. 2024 Feb;36(2):368-373.
doi: 10.1016/j.sdentj.2023.11.027. Epub 2023 Nov 28.

Retentive force and dislodgment time variations between three implant overdenture stud attachments in an acidic environment: An in-vitro pilot study

Affiliations

Retentive force and dislodgment time variations between three implant overdenture stud attachments in an acidic environment: An in-vitro pilot study

Maya Farhat et al. Saudi Dent J. 2024 Feb.

Abstract

Introduction: This in-vitro study aimed to evaluate the retentive force and dislodgment time of three stud attachment systems used for mandibular two-implant overdentures by simulating insertion/removal cycles.

Materials and methods: From a simulation of a completely edentulous mandible with two parallel implants (Ø4.5 mm internal hex connection) (Zimmer Biomet, Warsaw, IN), 15 resin bases were fabricated and divided into three groups (n = 5 each): OT Equator (Rhein83, Bologna, IT), Locator (Zest Dental Solutions, Escondido, CA) and Locator R-Tx (Zest Dental Solutions, Escondido, CA). Pink inserts underwent 2000 cycles of thermocycling (SD MECHATRONIK GmbH, Feldkirchen-Westerham, Germany) and were soaked in citric acid for 24 days in an incubator. Each base underwent 2000 insertion/removal cycles on the Versa Test testing machine (Mecmesin Ltd., W. Sussex, UK) which was used to measure the retentive force and dislodgment time. The results were analyzed using ANOVA followed by the post-hoc Tukey test, Kruskal-Wallis test, and Pearson correlation coefficient test. A p-value of < 0.05 was considered statistically significant.

Results: The retentive force and dislodgment time of the three systems significantly decreased over the cycles (p < 0.05). The Locator R-Tx showed significantly greater retentive force ​​than did the other systems (p < 0.05), except for the last cycles wherein no significant difference was found with the OT Equator (p > 0.05). The OT Equator had the most stable retention over the cycles (p > 0.05; cycle 1500).

Conclusion: The three systems showed satisfactory retentive force ​​during the 2000 cycles. The Locator R-Tx demonstrated the best retention, while the OT Equator exhibited the most stable retention over time.

Keywords: Attachment systems; Cyclic dislodging; Dislodgment time; Implant overdentures; In-vitro study; Retention.

PubMed Disclaimer

Conflict of interest statement

The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Figures

Fig. 1
Fig. 1
Simulation of the completely edentulous mandible with two parallel implants (left); mounting on the Versa Test testing machine (right).
Fig. 2
Fig. 2
Results of the retention forces in Newton (N), and the dislodgment time in seconds (s) of the three attachment systems.

Similar articles

References

    1. Abdelkoui A., Berrada S., Fajri L., Abdedine A., Merzouk N. Attachement Locator ® : mode d’utilisation clinique, étape par étape, en prothèse amovible complète stabilisée sur implants. Actual. Odonto-Stomatol. 2016;5 doi: 10.1051/aos/2016075. - DOI
    1. Abi Nader S., de Souza R.F., Fortin D., De Koninck L., Fromentin O., Albuquerque Junior R.F. Effect of simulated masticatory loading on the retention of stud attachments for implant overdentures. J. Oral Rehabil. 2011;38 doi: 10.1111/j.1365-2842.2010.02145.x. - DOI - PubMed
    1. Ahuja S., Cagna D.R. Classification and management of restorative space in edentulous implant overdenture patients. J. Prosthet. Dent. 2011;105:332–337. doi: 10.1016/S0022-3913(11)60064-4. - DOI - PubMed
    1. Al-Ghafli S.A., Michalakis K.X., Hirayama H., Kang K. The in Vitro Effect of Different Implant Angulations and Cyclic Dislodgement on the Retentive Properties of an Overdenture Attachment System. J. Prosthet. Dent. 2009;102:140–147. doi: 10.1016/S0022-3913(09)60134-7. - DOI - PubMed
    1. Besimo, C.E., Guarneri, A., 2003. In vitro retention force changes of prefabricated attachments for overdentures. J. Oral Rehabil. 30, 7, 671–678. https://pubmed.ncbi.nlm.nih.gov/12791150/. - PubMed

LinkOut - more resources