. 2024 Mar 1;106-B(3 Supple A):38-43.
doi: 10.1302/0301-620X.106B3.BJJ-2023-0836.R1.

Long-term polyethylene wear rates and clinical outcomes of oxidized zirconium femoral heads on highly cross-linked polyethylene in total hip arthroplasty

Affiliations

Long-term polyethylene wear rates and clinical outcomes of oxidized zirconium femoral heads on highly cross-linked polyethylene in total hip arthroplasty

Brandt C Buckner et al. Bone Joint J. .

Abstract

Aims: Oxidized zirconium (OxZi) and highly cross-linked polyethylene (HXLPE) were developed to minimize wear and risk of osteolysis in total hip arthroplasty (THA). However, retrieval studies have shown that scratched femoral heads may lead to runaway wear, and few reports of long-term results have been published. The purpose of this investigation is to report minimum ten-year wear rates and clinical outcomes of THA with OxZi femoral heads on HXLPE, and to compare them with a retrospective control group of cobalt chrome (CoCr) or ceramic heads on HXLPE.

Methods: From 2003 to 2006, 108 THAs were performed on 96 patients using an OxZi head with a HXLPE liner with minimum ten-year follow-up. Harris Hip Scores (HHS) were collected preoperatively and at the most recent follow-up (mean 13.3 years). Linear and volumetric liner wear was measured on radiographs of 85 hips with a minimum ten-year follow-up (mean 14.5 years). This was compared to a retrospective control group of 45 THAs using ceramic or CoCr heads from October 1999 to February 2005, with a minimum of ten years' follow-up.

Results: Average HHS improved from 50.8 to 91.9 and 51.0 to 89.8 in the OxZi group and control group, respectively (p = 0.644), with no osteolysis in either group. Linear and volumetric wear rates in the OxZi group averaged 0.03 mm/year and 3.46 mm3/year, respectively. There was no statistically significant difference in HHS scores, nor in linear or volumetric wear rate between the groups, and no revision for any indication.

Conclusion: The radiological and clinical outcomes, and survivorship of THA with OxZi femoral heads and HXLPE liners, were excellent, and comparable to CoCr or ceramic heads at minimum ten-year follow-up. Wear rates are below what would be expected for development of osteolysis. OxZi-HXLPE is a durable bearing couple with excellent long-term outcomes.

PubMed Disclaimer

Conflict of interest statement

K. L. Garvin reports receipt of support for attending meetings and/or travel for the American Board of Orthopaedic Surgery and Directorship and Committee Membership of same.

Similar articles

References

    1. Kurtz SM , Lau E , Ong K , Zhao K , Kelly M , Bozic KJ . Future young patient demand for primary and revision joint replacement: national projections from 2010 to 2030 . Clin Orthop Relat Res . 2009 ; 467 ( 10 ): 2606 – 2612 . 10.1007/s11999-009-0834-6 19360453
    1. Otten R , van Roermund PM , Picavet HSJ . [Trends in the number of knee and hip arthroplasties: considerably more knee and hip prostheses due to osteoarthritis in 2030] . Ned Tijdschr Geneeskd . 2010 ; 154 : A1534. [Article in Dutch] . 20619009
    1. Calvert GT , Devane PA , Fielden J , Adams K , Horne JG . A double-blind, prospective, randomized controlled trial comparing highly cross-linked and conventional polyethylene in primary total hip arthroplasty . J Arthroplasty . 2009 ; 24 ( 4 ): 505 – 510 . 10.1016/j.arth.2008.02.011 18547784
    1. Mu Z , Tian J , Wu T , Yang J , Pei F . A systematic review of radiological outcomes of highly cross-linked polyethylene versus conventional polyethylene in total hip arthroplasty . Int Orthop . 2009 ; 33 ( 3 ): 599 – 604 . 10.1007/s00264-008-0716-7 19184008
    1. Hanna SA , Somerville L , McCalden RW , Naudie DD , MacDonald SJ . Highly cross-linked polyethylene decreases the rate of revision of total hip arthroplasty compared with conventional polyethylene at 13 years’ follow-up . Bone Joint J . 2016 ; 98-B ( 1 ): 28 – 32 . 10.1302/0301-620X.98B1.36527 26733512