Comparison of cognitive workload and surgical outcomes between a three-dimensional and conventional microscope macular hole surgery
- PMID: 38429711
- PMCID: PMC10908162
- DOI: 10.1186/s12886-024-03361-5
Comparison of cognitive workload and surgical outcomes between a three-dimensional and conventional microscope macular hole surgery
Abstract
Background: Performing a surgical task subjects the surgeon to multitudinal stressors, especially with the newer 3D technology. The quantum of cognitive workload using this modern surgical system in comparison to the Conventional microscope system remains unexplored. We evaluate the surgeon's cognitive workload and the surgical outcomes of macular hole(MH) surgery performed on a 3D versus a Conventional microscope operating system.
Methods: 50 eyes of 50 patients with MH undergoing surgery using the 3D or Conventional microscope visualization system. Cognitive workload assessment was done by real-time tools(Surgeons' heart rate [HR] and oxygen saturation[SPO2]) and self-report tool(Surgery Task Load Index[SURG-TLX] questionnaire) of three Vitreoretinal surgeons. Based on the SURG-TLX questionnaire, an assessment of the workload was performed.
Results: Of the 50 eyes, 30 eyes and 20 eyes underwent surgery with the Conventional microscope and the 3D system, respectively. No difference was noted in the MH basal-diameter(p = 0.128), total surgical-duration(p = 0.299), internal-limiting membrane(ILM) peel time(p = 0.682), and the final visual acuity (VA; p = 0.515) between the two groups. Both groups showed significant improvement in VA(p < 0.001) with a 90% closure rate at one-month post-surgery. Cognitive workload comparison, the intraoperative HR(p = 0.024), total workload score(P = 0.005), and temporal-demand dimension(p = 0.004) were significantly more in Conventional microscope group as compared to 3D group. In both the groups, the HR increased significantly from the baseline while performing ILM peeling and at the end.
Conclusion: The surgeon's cognitive workload is markedly reduced while performing macular hole surgery with a 3D viewing system. Moreover, duration of surgery including ILM peel time, MH closure rates, and visual outcomes remains unaffected irrespective of the operating microscope system.
Keywords: 3D viewing system; Cognitive workload; Conventional microscope; Macular Hole.
© 2024. The Author(s).
Conflict of interest statement
The authors declare no competing interests.
Similar articles
-
Comparison of clinical outcomes between "heads-up" 3D viewing system and conventional microscope in macular hole surgeries: A pilot study.Indian J Ophthalmol. 2018 Dec;66(12):1816-1819. doi: 10.4103/ijo.IJO_59_18. Indian J Ophthalmol. 2018. PMID: 30451186 Free PMC article. Clinical Trial.
-
Comparing clinical outcomes of macular hole surgeries performed by trainee surgeons using a 3D heads-up display viewing system versus a standard operating microscope.Int Ophthalmol. 2021 Aug;41(8):2649-2655. doi: 10.1007/s10792-021-01792-3. Epub 2021 Jun 28. Int Ophthalmol. 2021. PMID: 34184150
-
EFFECT OF INVERTED INTERNAL LIMITING MEMBRANE FLAP ON CLOSURE RATE, POSTOPERATIVE VISUAL ACUITY, AND RESTORATION OF OUTER RETINAL LAYERS IN PRIMARY IDIOPATHIC MACULAR HOLE SURGERY.Retina. 2020 Oct;40(10):1955-1963. doi: 10.1097/IAE.0000000000002707. Retina. 2020. PMID: 31834129
-
Complete ILM Peeling Versus Inverted Flap Technique for Macular Hole Surgery: A Meta-Analysis.Ophthalmic Surg Lasers Imaging Retina. 2020 Mar 1;51(3):187-A2. doi: 10.3928/23258160-20200228-08. Ophthalmic Surg Lasers Imaging Retina. 2020. PMID: 32211909 Review.
-
Anatomical and visual outcomes in high myopic macular hole (HM-MH) without retinal detachment: a review.Graefes Arch Clin Exp Ophthalmol. 2014 Feb;252(2):191-9. doi: 10.1007/s00417-013-2555-5. Epub 2014 Jan 3. Graefes Arch Clin Exp Ophthalmol. 2014. PMID: 24384802 Review.
Cited by
-
Pioneering evaluation in Brazil of microscope-integrated optical coherence tomography with a three-dimensional digital visualization system during pars plana vitrectomy for the treatment of macular hole.Int J Retina Vitreous. 2025 May 19;11(1):57. doi: 10.1186/s40942-025-00671-8. Int J Retina Vitreous. 2025. PMID: 40383771 Free PMC article.
-
New Mixed Reality Headset: First Exploratory Use in Intraocular Surgery and Telementoring.Ophthalmol Ther. 2025 Jul;14(7):1597-1609. doi: 10.1007/s40123-025-01117-y. Epub 2025 Apr 11. Ophthalmol Ther. 2025. PMID: 40214829 Free PMC article.
References
MeSH terms
LinkOut - more resources
Full Text Sources