Abstract
Objectives: The effect of three-dimensional (3D) printed bone-attached guide plate assisted cannulated screw fixation of pelvic fracture is reliable, but extensive soft tissue dissection is still required when installing the guide plate. This study aims to compare the efficacy of posterior pelvic ring fracture fixation with iliosacral screw insertion between the assistance of modified percutaneous patient specific 3D printed guide template and conventional fluoroscopy.
Methods: From May, 2019 and September 2021, 28 patients sustained posterior pelvic ring fractures were randomized into 2 groups: A guide template group, in which the iliosacral screw was inserted for fixation of the posterior pelvic ring fracture with the assistance of modified percutaneous patient specific 3D printed guide template, and a fluoroscopy group, in which the iliosacral screw was inserted under the guidance of conventional fluoroscopy. The operation time, fluoroscopic frequency, intraoperative blood loss, and incision length were recorded for each screw insertion. Fracture reduction was evaluated according to the Matta criteria. The screw position was evaluated according to the modified Gras classification, and the functional outcome was evaluated according to Majeed score. The parameters of both groups were compared, and statistical analysis was performed.
Results: All the 28 patients were followed up for 12-24 months. Of them, 15 iliosacral screws were inserted in 14 patients in the guide template group, and 14 iliosacral screws were inserted in 14 patients in the fluoroscopy group. The operation time, fluoroscopic frequency, screw deviation, incision length, and blood loss in the guide template group were 20-30(25.8±2.8) min, 9-15(12.2±1.9), 2-4(2.6±0.7) mm, 4-5(4.6±0.5) cm, and 5-10 (7.8±1.7) mL, respectively, whereas those in the fluoroscopy group were 30-60(48.1±7.5) min, 40-96(64.7±16.3), 3-6(4.2±0.9) mm, 0.8-1.2(1.0±0.1) cm, and 2-5(3.1±1.3) mL, respectively, and there were statistical significance (all P<0.001). Fracture reduction was evaluated according to the Matta criteria, and all the patients reached excellence and good (P=0.584) in the 2 groups. According to modified Gras classification, there were 12 Grade I screws, 3 Grade II screws, and 0 Grade III screws in the guide template group, and 10 Grade I screws, 3 Grade II screws, and 1 Grade III screw in the fluoroscopy group, with no statistical significance (P=0.334). The functional outcome was evaluated according to Majeed score at the last follow-up, without significant difference between the guide template group and the fluoroscopy group (P=0.908).
Conclusions: Compared with the conventional fluoroscopy, it would cost less operation time, less fluoroscopic frequency and increase more accurate screw insertion to fixate the posterior pelvic ring fracture with the assistance of modified percutaneous patient specific 3D printed guide template.
目的: 三维打印(以下简称“3D打印”)贴骨导板辅助空心螺钉固定骨盆骨折疗效可靠,但安装导板时需要较广泛的软组织剥离。本研究旨在比较改良经皮3D打印导板与传统透视下辅助骶髂螺钉植入治疗骨盆后环骨折的临床效果。方法: 收集2019年5月至2021年9月诊治的骨盆后环骨折患者28例,并随机分为2组。导板组采用改良经皮导板辅助骶髂螺钉固定骨盆后环骨折;透视组采用透视辅助骶髂螺钉固定骨盆后环骨折。记录2组每枚螺钉植入的手术时间、透视次数、术中出血量和切口长度。根据Matta标准评价骨折复位情况,分别按照改良Gras分类和Majeed功能评分系统评估螺钉位置和患者功能恢复情况,并进行统计学分析。结果: 28例患者均获随访12~24个月,其中导板组14例患者植入15枚骶髂螺钉,透视组14例患者植入14枚骶髂螺钉。导板组和透视组手术时间分别为20~30(25.8±2.8) min和30~60(48.1±7.5) min (P<0.001),透视次数分别为9~15(12.2±1.9)和40~96(64.7±16.3)(P<0.001),螺钉偏移分别为2~4(2.6±0.7) mm和3~6(4.2±0.9) mm (P<0.001),切口长度分别为4~5(4.6±0.5) cm和0.8~1.2(1.0±0.1) cm (P<0.001),术中出血量分别为5~10(7.8±1.7) mL和2~5(3.1±1.3) mL(P<0.001)。2组骨折复位Matta标准评分均达到优、良(P=0.584)。改良Gras分类评估螺钉位置:导板组I类12枚,II类3枚,III类0枚;透视组I类10枚,II类3枚,III类1枚。2组比较差异无统计学意义(P=0.334)。末次随访Majeed功能评分导板组与透视组比较差异无统计学意义(P=0.908)。结论: 改良经皮3D打印导板辅助骶髂螺钉固定骨盆后环骨折对比传统透视辅助骶髂螺钉固定骨盆后环骨折可缩短手术时间,减少透视次数,提高植钉的准确性。.
Keywords: fracture fixation; guide template; iliosacral screw; pelvis; three-dimensional printing.
Conflict of interest statement
作者声称无任何利益冲突。
Figures

Similar articles
-
Iliosacral screw fixation of pelvic ring disruption with tridimensional patient-specific template guidance.Orthop Traumatol Surg Res. 2022 Apr;108(2):103210. doi: 10.1016/j.otsr.2022.103210. Epub 2022 Jan 22. Orthop Traumatol Surg Res. 2022. PMID: 35077898
-
[Treatment of unstable pelvic fractures by cannulated screw internal fixation with the assistance of three-dimensional printing insertion template].Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2018 Feb 15;32(2):145-151. doi: 10.7507/1002-1892.201708059. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2018. PMID: 29806402 Free PMC article. Chinese.
-
[Effectiveness of sacroiliac screw implantation assisted by three-dimensional printed faceted honeycomb guide plate in treatment of posterior pelvic ring fracture].Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2024 Nov 15;38(11):1317-1324. doi: 10.7507/1002-1892.202405078. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2024. PMID: 39542621 Free PMC article. Chinese.
-
Clinical Application of Navigation in the Surgical Treatment of a Pelvic Ring Injury and Acetabular Fracture.Adv Exp Med Biol. 2018;1093:289-305. doi: 10.1007/978-981-13-1396-7_22. Adv Exp Med Biol. 2018. PMID: 30306489 Review.
-
Plate versus sacroiliac screw fixation for treating posterior pelvic ring fracture: a Systematic review and meta-analysis.Injury. 2020 Oct;51(10):2259-2266. doi: 10.1016/j.injury.2020.07.003. Epub 2020 Jul 3. Injury. 2020. PMID: 32646648
References
-
- 吴涛, 程晓东, 崔蕴威, 等. 不同内固定方式固定骶髂关节脱位的三维有限元分析[J]. 河北医科大学学报, 2018, 39(9): 1026-1030. 10.3969/j.issn.1007-3205.2018.09.008. - DOI
- WU Tao, CHENG Xiaodong, CUI Yunwei, et al. . Comparison of different kinds of internal fixation for sacroiliac joint dislocation: a finite element analysis[J]. Journal of Hebei Medical University, 2018, 39(9): 1026-1030. 10.3969/j.issn.1007-3205.2018.09.008. - DOI
Publication types
MeSH terms
Supplementary concepts