. 2024 Apr:149:7-12.
doi: 10.1016/j.placenta.2024.02.010. Epub 2024 Feb 28.

Two-dimensional (2D) placental ultrasound measurements - The correlation with placental volume measured by magnetic resonance imaging (MRI)

Affiliations
Free article

Two-dimensional (2D) placental ultrasound measurements - The correlation with placental volume measured by magnetic resonance imaging (MRI)

Karianne Sagberg et al. Placenta. 2024 Apr.
Free article

Abstract

Introduction: Information about placental size in ongoing pregnancies may aid the identification of pregnancies with increased risk of adverse outcome. Placental volume can be measured using magnetic resonance imaging (MRI). However, this method is not universally available in antenatal care. Ultrasound is the diagnostic tool of choice in pregnancy. Therefore, we studied whether simple two-dimensional (2D) ultrasound placental measurements were correlated with placental volume measured by MRI.

Methods: We examined a convenience sample of 104 ongoing pregnancies at gestational week 27, using both ultrasound and MRI. The ultrasound measurements included placental length, width and thickness. Placental volume was measured using MRI. The correlation between each 2D placental ultrasound measurement and placental volume was estimated by applying Pearson's correlation coefficient (r).

Results: Mean placental length was 17.2 cm (SD 2.1 cm), mean width was 14.7 cm (SD 2.1 cm), and mean thickness was 3.2 cm (SD 0.6 cm). Mean placental volume was 536 cm3 (SD 137 cm3). The 2D ultrasound measurements showed poor correlation with placental volume (placental length; r = 0.27, width; r = 0.37, and thickness r = 0.13).

Discussion: Simple 2D ultrasound measurements of the placenta were poorly correlated with placental volume and cannot be used as proximate measures of placental volume. Our finding may be explained by the large variation between pregnancies in intrauterine placental shape.

Keywords: 2D ultrasound; Magnetic resonance imaging; Placenta; Placental size; Placental thickness; Placental volume.

PubMed Disclaimer

Conflict of interest statement

Declaration of competing interest The authors report no conflict of interest.