Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Multicenter Study
. 2024 Aug;64(2):214-221.
doi: 10.1002/uog.27634. Epub 2024 Jul 5.

Implementation of sonopartogram: multicenter feasibility study

Affiliations
Free article
Multicenter Study

Implementation of sonopartogram: multicenter feasibility study

N M W Lee et al. Ultrasound Obstet Gynecol. 2024 Aug.
Free article

Abstract

Objectives: Well-established clinical practice for assessing progress in labor involves routine abdominal palpation and vaginal examination (VE). However, VE is subjective, poorly reproducible and painful for most women. In this study, our aim was to evaluate the feasibility of systematically integrating transabdominal and transperineal ultrasound assessment of fetal position, parasagittal angle of progression (psAOP), head-perineum distance (HPD) and sonographic cervical dilatation (SCD) to monitor the progress of labor in women undergoing induction of labor (IOL). We also aimed to determine if ultrasound can reduce women's pain during such examinations.

Methods: Women were recruited as they presented for IOL in three maternity units. Ultrasound assessments were performed in 100 women between 37 + 0 and 41 + 6 weeks' gestation. A baseline combined transabdominal and transperineal scan was performed, including assessment of fetal biometry, umbilical artery and fetal middle cerebral artery Doppler, amniotic fluid index, fetal spine and occiput positions, psAOP, HPD, SCD and cervical length. Intrapartum scans were performed instead of VE, unless there was a clinical indication to perform a VE, according to protocol. Participants were asked to indicate their level of pain by verbally giving a pain score between 0 and 10 (with 0 representing no pain) during assessment. Repeated measures data were analyzed using mixed-effect models to identify significant factors that affected the relationship between psAOP, HPD, SCD and mode of delivery.

Results: A total of 100 women were included in the study. Of these, 20% delivered by Cesarean section, 65% vaginally and 15% by instrumental delivery. There were no adverse fetal or maternal outcomes. A total of 223 intrapartum ultrasound scans were performed in 87 participants (13 women delivered before intrapartum ultrasound was performed), with a median of two scans per participant (interquartile range (IQR), 1-3). Of these, 76 women underwent a total of 151 VEs with a median of one VE per participant (IQR, 0-2), with no significant difference between vaginal- or Cesarean-delivery groups. After excluding those with epidural anesthesia during examination, the median pain score for intrapartum scans was 0 (IQR, 0-1) and for VE it was 3 (IQR, 0-6). Cesarean delivery was significantly associated with a slower rate of change in psAOP, HPD and SCD.

Conclusions: Comprehensive transabdominal and transperineal ultrasound assessment can be used to assess progress in labor and can reduce the level of pain experienced during examination. Ultrasound assessment may be able to replace some transabdominal and vaginal examinations during labor. © 2024 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

Keywords: AOP; HPD; SCD; angle of progression; caput succedaneum; cervical dilatation; feasibility; fetal head station; head–perineum distance; parasagittal angle of progression; sonographic cervical dilation; transperineal ultrasound.

PubMed Disclaimer

Similar articles

Cited by

References

REFERENCES

    1. Dupuis O, Silveira R, Zentner A, et al. Birth simulator: reliability of transvaginal assessment of fetal head station as defined by the American College of Obstetricians and Gynecologists classification. Am J Obstet Gynecol. 2005;192(3):868‐874.
    1. Buchmann EJ, Libhaber E. Accuracy of cervical assessment in the active phase of labour. BJOG. 2007;114(7):833‐837.
    1. Chan YT, Ng KS, Yung WK, Lo TK, Lau WL, Leung WC. Is intrapartum translabial ultrasound examination painless? J Matern Fetal Neonatal Med. 2016;29(20):3276‐3280.
    1. Soper DE, Mayhall CG, Dalton HP. Risk factors for intraamniotic infection: a prospective epidemiologic study. Am J Obstet Gynecol. 1989;161(3):562‐566. discussion 6‐8.
    1. Oberman M, Avrahami I, Lavi Shoseyov N, et al. Assessment of labor progress by ultrasound vs manual examination: a randomized controlled trial. Am J Obstet Gynecol MFM. 2023;5(2):100817.

Publication types

LinkOut - more resources