Positive Pressure Ventilation in Preterm Infants in the Delivery Room: A Review of Current Practices, Challenges, and Emerging Technologies
- PMID: 38467119
- DOI: 10.1159/000537800
Positive Pressure Ventilation in Preterm Infants in the Delivery Room: A Review of Current Practices, Challenges, and Emerging Technologies
Abstract
Background: A major proportion of preterm neonates require positive pressure ventilation (PPV) immediately after delivery. PPV may be administered through a face mask (FM) or nasal prongs. Current literature indicates that either of these are associated with similar outcomes.
Summary: Nonetheless, FM remains the most utilized and the best choice. However, most available FM sizes are too large for extremely preterm infants, which leads to mask leak and ineffective PPV. Challenges to providing effective PPV include poor respiratory drive, complaint chest wall, weak thoracic muscle, delayed liquid clearance, and surfactant deficiency in preterm infants. Mask leak, airway obstruction, poor technique, and inappropriate size are correctable causes of ineffective PPV. Visual assessment of chest rise is often used to assess the efficacy of PPV. However, its accuracy is debatable. Though end tidal CO2 may adjudge the effectiveness of PPV, clinical studies are limited. The compliance of a preterm lung is highly dynamic. The inflating pressure set on T-piece is constant throughout the resuscitation, but the lung volume and dynamics changes with every breath. This leads to huge fluctuations of tidal volume delivery and can trigger inflammatory cascade in preterm infants leading to brain and lung injury. Respiratory function monitoring in the delivery room has potential for guiding and optimizing delivery room resuscitation. This is, however, limited by high costs, complex information that is difficult to interpret during resuscitation, and absence of clinical trials.
Key messages: This review summarizes the existing literature on PPV in preterm infants, the various aspects related to it such as the pathophysiology, interfaces, devices utilized to deliver it, appropriate technique, emerging technologies, and future directions.
Keywords: Delivery room; Infants; Newborn; Newborn resuscitation.
© 2024 S. Karger AG, Basel.
Similar articles
-
A randomized trial of oropharyngeal airways to assist stabilization of preterm infants in the delivery room.Resuscitation. 2019 Nov;144:106-114. doi: 10.1016/j.resuscitation.2019.08.035. Epub 2019 Sep 10. Resuscitation. 2019. PMID: 31518615 Clinical Trial.
-
Supporting breathing of preterm infants at birth: a narrative review.Arch Dis Child Fetal Neonatal Ed. 2019 Jan;104(1):F102-F107. doi: 10.1136/archdischild-2018-314898. Epub 2018 Jul 26. Arch Dis Child Fetal Neonatal Ed. 2019. PMID: 30049727 Review.
-
Mask ventilation with two different face masks in the delivery room for preterm infants: a randomized controlled trial.J Perinatol. 2015 Jul;35(7):464-8. doi: 10.1038/jp.2015.8. Epub 2015 Feb 26. J Perinatol. 2015. PMID: 25719544 Clinical Trial.
-
Assessment of chest rise during mask ventilation of preterm infants in the delivery room.Resuscitation. 2011 Feb;82(2):175-9. doi: 10.1016/j.resuscitation.2010.10.012. Epub 2010 Nov 12. Resuscitation. 2011. PMID: 21074926
-
Mask versus Prongs for Nasal Continuous Positive Airway Pressure in Preterm Infants: A Systematic Review and Meta-Analysis.Neonatology. 2019;116(2):100-114. doi: 10.1159/000496462. Epub 2019 Jun 4. Neonatology. 2019. PMID: 31163418
Cited by
-
Respiratory Function Monitoring and Visual Attention in Resuscitating Term Infants: A Manikin-Based Randomised Crossover Trial.Acta Paediatr. 2025 Oct;114(10):2565-2570. doi: 10.1111/apa.70141. Epub 2025 May 28. Acta Paediatr. 2025. PMID: 40433860 Free PMC article. Clinical Trial.
-
Non-Invasive Ventilatory Support in Preterm Neonates in the Delivery Room and the Neonatal Intensive Care Unit: A Short Narrative Review of What We Know in 2024.Neonatology. 2024;121(5):576-583. doi: 10.1159/000540601. Epub 2024 Aug 22. Neonatology. 2024. PMID: 39173610 Free PMC article. Review.
-
High-flow nasal cannula for stabilisation of very premature infants: A prospective observational study.Acta Paediatr. 2025 May;114(5):986-991. doi: 10.1111/apa.17519. Epub 2024 Nov 25. Acta Paediatr. 2025. PMID: 39584601 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical