Continuous positive airway pressure treatment in sleep apnea: patient compliance and impact on the right heart
- PMID: 38469074
- PMCID: PMC10897640
- DOI: 10.1007/s41105-021-00340-x
Continuous positive airway pressure treatment in sleep apnea: patient compliance and impact on the right heart
Abstract
Obstructive sleep apnea syndrome (OSAS) is considered to be an important predisposing factor for cardiovascular diseases. The main objective of this study was to investigate the impact of CPAP treatment on cardiac structure and function and to assess patient compliance over a long-term course of CPAP treatment. A total of 50 patients diagnosed with moderate-to-severe OSAS based on overnight study, without relevant concomitant diseases were enrolled. Patient compliance, along with echocardiographic and CPAP parameters, was assessed. The average time to follow-up was 38 ± 4.2 months. An increase in tricuspid annular plane systolic excursion (TAPSE) (22.1 ± 4.3-25.5 ± 4.6 mm, p = 0.005) and peak early systolic tricuspid annular velocity (S') (14 ± 3.2-17.2 ± 5.2 cm/s, p = 0.005) after CPAP treatment was noted. In patients without CPAP, no significant change in right ventricular (RV) contractility was found. There were no significant differences regarding right atrial (RA) and RV diameters, as well as tricuspid regurgitant peak gradient (TRPG) in both groups; however, a predisposition to increased RA size along with RV and tricuspid annulus diameters was revealed. The mean duration of nightly CPAP use was 3 ± 2.3 h/night in all-day analysis and 4.7 ± 2.1 h/night on days with device usage. The non-adherence rate was 57%. The use of effective CPAP therapy may lead to increased RV systolic function in patients with OSAS in long-term observation. However, long-term patient compliance is generally poor. Regardless of CPAP therapy, a gradual increase in heart size is observed.
Keywords: Echocardiography; OSAS; Polysomnography.
© The Author(s) 2021.
Conflict of interest statement
Conflicts of interestThe authors declare that there is no conflict of interest.
Figures
Similar articles
-
Influence of obstructive sleep apnea on right heart structure and function.Adv Respir Med. 2021;89(5):493-500. doi: 10.5603/ARM.a2021.0095. Epub 2021 Sep 27. Adv Respir Med. 2021. PMID: 34569612
-
Effects of continuous positive airway pressure therapy on right ventricular function assessment by tissue Doppler imaging in patients with obstructive sleep apnea syndrome.Echocardiography. 2008 Nov;25(10):1071-8. doi: 10.1111/j.1540-8175.2008.00731.x. Epub 2008 Sep 2. Echocardiography. 2008. PMID: 18771543 Clinical Trial.
-
Evaluation of right ventricular performance and impact of continuous positive airway pressure therapy in patients with obstructive sleep apnea living at high altitude.Sci Rep. 2020 Nov 19;10(1):20186. doi: 10.1038/s41598-020-71584-9. Sci Rep. 2020. PMID: 33214634 Free PMC article.
-
Impact of continuous positive airway pressure treatment on myocardial performance in patients with obstructive sleep apnea. A conventional and tissue Doppler echocardiographic study.Sleep Breath. 2015 Mar;19(1):343-50. doi: 10.1007/s11325-014-1026-5. Epub 2014 Jul 3. Sleep Breath. 2015. PMID: 24989483
-
The impact of continuous positive airway pressure on cardiac mechanics: Findings from a meta-analysis of echocardiographic studies.J Clin Hypertens (Greenwich). 2022 Jul;24(7):795-803. doi: 10.1111/jch.14488. Epub 2022 Jun 13. J Clin Hypertens (Greenwich). 2022. PMID: 35695237 Free PMC article.
Cited by
-
The AutoStrain LV technique is a sensitive method for detecting subclinical left ventricular dysfunction in patients with obstructive sleep apnea syndrome.Medicine (Baltimore). 2025 May 2;104(18):e42309. doi: 10.1097/MD.0000000000042309. Medicine (Baltimore). 2025. PMID: 40324252 Free PMC article.
References
LinkOut - more resources
Full Text Sources