Optical Sensor System for 3D Jones Matrix Reconstruction of Optical Anisotropy Maps of Self-Assembled Polycrystalline Soft Matter Films
- PMID: 38475128
- PMCID: PMC10933998
- DOI: 10.3390/s24051589
Optical Sensor System for 3D Jones Matrix Reconstruction of Optical Anisotropy Maps of Self-Assembled Polycrystalline Soft Matter Films
Abstract
Our work uses a polarization matrix formalism to analyze and algorithmically represent optical anisotropy by open dehydration of blood plasma films. Analytical relations for Jones matrix reconstruction of optical birefringence maps of protein crystal networks of dehydrated biofluid films are found. A technique for 3D step-by-step measurement of the distributions of the elements of the Jones matrix or Jones matrix images (JMI) of the optically birefringent structure of blood plasma films (BPF) has been created. Correlation between JMI maps and corresponding birefringence images of dehydrated BPF and saliva films (SF) obtained from donors and prostate cancer patients was determined. Within the framework of statistical analysis of layer-by-layer optical birefringence maps, the parameters most sensitive to pathological changes in the structure of dehydrated films were found to be the central statistical moments of the 1st to 4th orders. We physically substantiated and experimentally determined the sensitivity of the method of 3D polarization scanning technique of BPF and SF preparations in the diagnosis of endometriosis of uterine tissue.
Keywords: 3D reconstruction; Jones matrix; blood plasma; diagnostics; optical anisotropy.
Conflict of interest statement
The authors declare no conflicts of interest.
Figures



Similar articles
-
Birefringence images of polycrystalline films of human urine in early diagnostics of kidney pathology.Appl Opt. 2016 Apr 20;55(12):B85-90. doi: 10.1364/AO.55.000B85. Appl Opt. 2016. PMID: 27140137
-
Differential Mueller matrix imaging of partially depolarizing optically anisotropic biological tissues.Lasers Med Sci. 2020 Jun;35(4):877-891. doi: 10.1007/s10103-019-02878-2. Epub 2019 Nov 20. Lasers Med Sci. 2020. PMID: 31749042 Free PMC article.
-
Insights into polycrystalline microstructure of blood films with 3D Mueller matrix imaging approach.Sci Rep. 2024 Jun 13;14(1):13679. doi: 10.1038/s41598-024-63816-z. Sci Rep. 2024. PMID: 38871757 Free PMC article.
-
Recent Development of SnII , SbIII -based Birefringent Material: Crystal Chemistry and Investigation of Birefringence.Angew Chem Int Ed Engl. 2023 Jun 26;62(26):e202302025. doi: 10.1002/anie.202302025. Epub 2023 Apr 14. Angew Chem Int Ed Engl. 2023. PMID: 36912564 Review.
-
Polarization-resolved Stokes-Mueller imaging: a review of technology and applications.Lasers Med Sci. 2019 Sep;34(7):1283-1293. doi: 10.1007/s10103-019-02752-1. Epub 2019 Mar 4. Lasers Med Sci. 2019. PMID: 30830559 Review.
References
-
- Tuchin V.V. Tissue Optics and Photonics: Light-Tissue Interaction. J. Biomed. Photonics Eng. 2015;1:98–134. doi: 10.18287/JBPE-2015-1-2-98. - DOI
MeSH terms
Substances
LinkOut - more resources
Full Text Sources