. 2024 Aug;28(4):989-1004.
doi: 10.1007/s10029-024-02996-z. Epub 2024 Mar 21.

The use of poly-4-hydroxybutyrate (P4HB, Phasix™) mesh in ventral hernia repair: a systematic review and meta-analysis

Affiliations
Meta-Analysis

The use of poly-4-hydroxybutyrate (P4HB, Phasix™) mesh in ventral hernia repair: a systematic review and meta-analysis

Daniel H Tran et al. Hernia. 2024 Aug.

Abstract

Purpose/background: Despite the growing use of bioabsorbable mesh in ventral hernia repairs (VHR), the evidence of its impact on patient outcomes remains limited. This study aims to investigate the efficacy and safety profile of poly-4-hydroxybutyrate (P4HB) mesh for ventral hernia repair through a systematic review and meta-analysis.

Methods: A literature search of five databases (PubMed, Embase, Ovid, Medline, and Google Scholar) produced a list of publications that analyzed the use of P4HB mesh in ventral hernia repair in both clean and contaminated cases. The primary postoperative outcomes of hernia recurrence, surgical site infections (SSI), and any complications were analyzed through a pooled meta-analysis.

Results: In our systematic review, 21 studies met the inclusion criteria with a total of 1858 patients (933 males and 925 females) and an average age of 56.8 years. The median follow-up ranged from 1.6 to 62.3 months. In our meta-analysis, the use of P4HB mesh in VHR in proportion of events demonstrated a recurrence rate of 9% [6%; 15%], SSI of 10% [6%; 16%] and 35% [9%; 42%] for rate of any complications. Sub-meta-analysis restricted to studies with follow up > 18 months continues to show low rates of recurrence of 9% (95%CI, 4-17%), SSI of 9% (95%CI, 4-16%), and 31% (95%CI, 23-41%) for any complications.

Conclusion: Our study demonstrates that the use of P4HB mesh is both safe and effective in ventral hernia repairs. When further analyzed past 18 months, the time where P4HB mesh fully resorbs, the rates of hernia recurrence, SSI, and any complications remain low of upwards of 5 years and comparable to the rates seen in synthetic and biologics in similar patient populations.

Keywords: Bioabsorbable mesh; Hernia; Phasix; Poly-4-hydroxybutyrate.

PubMed Disclaimer

References

    1. Bedewi MA, El-Sharkawy MS, Al Boukai AA, Al-Nakshabandi N (2012) Prevalence of adult paraumbilical hernia. Assessment by high-resolution sonography: a hospital-based study. Hernia 16(1):59–62. https://doi.org/10.1007/s10029-011-0863-4 . (PMID: 21796449)
    1. Kadakia N, Mudgway R, Vo J et al (2020) Long-term outcomes of ventral hernia repair: an 11-year follow-up. Cureus 12(8):e9523. Published 2020 Aug 2. https://doi.org/10.7759/cureus.9523 . (PMID: 32905150)
    1. Reynolds D, Davenport DL, Korosec RL, Roth JS (2013) Financial implications of ventral hernia repair: a hospital cost analysis. J Gastrointest Surg 17(1):159–167. https://doi.org/10.1007/s11605-012-1999-y . (PMID: 22965649)
    1. Harth KC, Krpata DM, Chawla A, Blatnik JA, Halaweish I, Rosen MJ (2013) Biologic mesh use practice patterns in abdominal wall reconstruction: a lack of consensus among surgeons. Hernia 17(1):13–20. https://doi.org/10.1007/s10029-012-1029-8 . (PMID: 23269402) - DOI - PubMed
    1. Deeken CR, Lake SP (2017) Mechanical properties of the abdominal wall and biomaterials utilized for hernia repair. J Mech Behav Biomed Mater 74:411–427. https://doi.org/10.1016/j.jmbbm.2017.05.008 . (Epub 2017 May 6. PMID: 28692907) - DOI - PubMed

LinkOut - more resources