Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2024:27:47-51.
doi: 10.1053/j.pcsu.2024.01.007. Epub 2024 Jan 24.

Late Pulmonary Autograft Dilation: Can We Make a Good Operation Great? The Supported Ross

Affiliations
Review

Late Pulmonary Autograft Dilation: Can We Make a Good Operation Great? The Supported Ross

Michael E Mitchell et al. Semin Thorac Cardiovasc Surg Pediatr Card Surg Annu. 2024.

Abstract

The Ross procedure is an excellent option for aortic valve replacement resulting in outstanding hemodynamic performance and the ability to avoid systemic anticoagulation. The long-term durability of the autograft is generally good but concerns for later aortic root dilation with ensuing neoaortic insufficiency have prompted efforts to stabilize the autograft, root, sinuses and Sino-tubular junction in order to delay or entirely avoid late reinterventions on the neoaortic root. We have employed an inclusion technique, supporting the Auto-graft in a Terumo Gelweave™ Valsalva graft. We performed a retrospective study of all 129 patients undergoing the Ross procedure from 1992 to 2019 at Children's Wisconsin. Fifty-one underwent the supported Ross (SR) and 78 underwent unsupported Ross (UR). Structured clinical data was collected and echocardiograms were reviewed. Median follow-up was 4.9 years (up to 22.6 years) for UR patients and 3.6 years (up to 11.4 years) for SR patients. In order to provide a fair comparison, we sub -analyzed patients aged 10 to 18 years who underwent the Ross procedure, 16 who underwent the UR and 18 patients who underwent the SR. Change in aortic annulus diameter (P = 0.002), aortic sinus diameter (P = 0.001) change in left ventricular function (P = 0.039) and change in aortic insufficiency (P = 0.008) were all worse in UR. The SR is simple, reproducible, and predictable. It seems to prevent change in annulus diameter, sinus diameter and to reduce late neoaortic insufficiency. Longer follow-up with a larger group of patients is required to draw definitive conclusions.

Keywords: Pediatric aortic valve replacement; Supported ross procedure.

PubMed Disclaimer

Conflict of interest statement

Declaration of competing interest The authors have no relevant conflicts of interest to disclose.

Similar articles

LinkOut - more resources