Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2024 Jun 1:220:67-76.
doi: 10.1016/j.amjcard.2024.03.030. Epub 2024 Apr 4.

Causes and Clinical Outcomes of Patients Who Failed Screening for Transcatheter Tricuspid Valve Interventions

Affiliations

Causes and Clinical Outcomes of Patients Who Failed Screening for Transcatheter Tricuspid Valve Interventions

Ghadi Moubarak et al. Am J Cardiol. .

Abstract

Transcatheter tricuspid valve intervention (TTVI) has recently emerged as a promising alternative to surgery for tricuspid regurgitation (TR). However, a significant proportion of patients fail screening for TTVI, and little is known about their characteristics and natural history. This study sought to investigate causes of screen failure and outcomes of patients declined for TTVI. This was a retrospective single-center study of 32 patients who were ineligible for participation in transcatheter tricuspid valve replacement and tricuspid transcatheter edge-to-edge repair trials. Patients were classified into 2 groups according to the therapy they received: optimized medical therapy (OMT) group or intervention group. The mean age was 82 ± 7.8 years and 68.8% were women. The most common reasons for TTVI exclusion were anatomic/procedural impediment (53.1%), inclusion criteria not met (40.6%), and multivalvular disease (6.3%). Overall, 19 patients (59.4%) did not undergo subsequent tricuspid intervention. The clinical outcomes of these patients who received OMT alone were poor, with a 1-year composite of cardiac death or heart failure readmission of 47.4%. These rates were worse than in patients who subsequently underwent an intervention, albeit not statistically significant (OMT: 47.7% vs 23.1% interventions, p = 0.3), and were significantly more pronounced in the subgroup of patients who were excluded for anatomic/procedural limitations (OMT: 70% vs 14.3% interventions, p = 0.05). In conclusion, patients ineligible for TTVI, particularly, those with anatomic/procedural limitations, and treated medically have poor outcomes. These data underscore the importance of earlier referral and support the need for further transcatheter therapy iterations.

Keywords: screen fail; transcatheter tricuspid valve replacement; tricuspid regurgitation; tricuspid transcatheter edge-to-edge repair.

PubMed Disclaimer

Conflict of interest statement

Declaration of competing interest Dr. Mack reports the following affiliations: Abbott - Trial Co-PI; Edwards Life sciences - Trial Co-PI; Medtronic - Trial Study Chair—all uncompensated. Dr. Szerlip reports the following affiliations: Edwards Lifesciences - proctor, speaker, consultant; Abbott Vascular - advisory board, consultant, proctor; Medtronic - steering committee; Boston Scientific - speaker, consultant. The remaining authors have no competing interests to declare.

LinkOut - more resources