The Influence of Kinetic Models and Attenuation Correction on Cadmium-Zinc-Telluride Single-Photon Emission Computed Tomography (CZT SPECT)-Derived Myocardial Blood Flow and Reserve: Correlation with Invasive Angiography Data
- PMID: 38592092
- PMCID: PMC10932033
- DOI: 10.3390/jcm13051271
The Influence of Kinetic Models and Attenuation Correction on Cadmium-Zinc-Telluride Single-Photon Emission Computed Tomography (CZT SPECT)-Derived Myocardial Blood Flow and Reserve: Correlation with Invasive Angiography Data
Abstract
(1) Background: The objective of this study was to determine the optimal post-processing model for dynamic cadmium-zinc-telluride single-photon emission computed tomography (CZT-SPECT). (2) Methods: A total of 235 patients who underwent diagnostic invasive coronary angiography within three months of the SPECT and those who had coronary computed tomography angiography (CCTA) before SPECT (within 3 months) were enrolled in this study. Each SPECT study was processed to obtain global and regional stress myocardial blood flow (sMBF), rest-MBF (rMBF), myocardial flow reserve (MFR) and flow difference (FD) estimates obtained with 1-tissue-compartment (1TCM) and net retention (NR) modes, both with and without attenuation correction. (3) Results: The use of AC led to significantly higher sMBF, rMBF and DF values obtained by 1TCM compared those values derived by 1TCM with NAC; the lowest values of stress MBF and rest MBF were obtained by 1TCM_NAC. The resting flow, MFR and DF were significantly (p < 0.005) higher in the AC model than in NAC. All quantitative variables were significantly (p < 0.05) higher in NR_NAC than in the 1TC_NAC model. Finally, sMBF, rMBF and FD showed significantly (p < 0.05) higher values by using 1TMC_AC compared to NR_AC. (4) Conclusions: We suggested that 1-compartment and net retention models correctly reflect coronary microcirculation and can be used for clinical practice for evaluating quantitative myocardial perfusion by dynamic SPECT. Attenuation correction is an important step in post-processing dynamic SPECT data, which increases the consistency and diagnostic accuracy of models.
Keywords: attenuation correction; coronary flow reserve; dynamic SPECT; kinetic models; myocardial blood flow.
Conflict of interest statement
The authors declare no conflicts of interest.
Similar articles
-
Comparison between N13NH3-PET and 99mTc-Tetrofosmin-CZT SPECT in the evaluation of absolute myocardial blood flow and flow reserve.J Nucl Cardiol. 2021 Oct;28(5):1906-1918. doi: 10.1007/s12350-019-01939-x. Epub 2019 Nov 14. J Nucl Cardiol. 2021. PMID: 31728817
-
Diagnostic analysis of new quantitative parameters of low-dose dynamic myocardial perfusion imaging with CZT SPECT in the detection of suspected or known coronary artery disease.Int J Cardiovasc Imaging. 2021 Jan;37(1):367-378. doi: 10.1007/s10554-020-01962-x. Epub 2020 Sep 10. Int J Cardiovasc Imaging. 2021. PMID: 32914404 Free PMC article.
-
[Diagnostic efficiency and incremental value of myocardial blood flow quantification by CZT SPECT for patients with coronary artery disease].Zhonghua Xin Xue Guan Bing Za Zhi. 2022 May 24;50(5):494-500. doi: 10.3760/cma.j.cn112148-20211124-01018. Zhonghua Xin Xue Guan Bing Za Zhi. 2022. PMID: 35589599 Chinese.
-
Myocardial blood flow evaluation with dynamic cadmium-zinc-telluride single-photon emission computed tomography: Bright and dark sides.Diagn Interv Imaging. 2023 Jul-Aug;104(7-8):323-329. doi: 10.1016/j.diii.2023.02.001. Epub 2023 Feb 14. Diagn Interv Imaging. 2023. PMID: 36797156 Review.
-
The current status of CZT SPECT myocardial blood flow and reserve assessment: Tips and tricks.J Nucl Cardiol. 2022 Dec;29(6):3137-3151. doi: 10.1007/s12350-021-02620-y. Epub 2021 Apr 30. J Nucl Cardiol. 2022. PMID: 33939162 Review.
References
-
- Murthy V.L., Bateman T.M., Beanlands R.S., Berman D.S., Borges-Neto S., Chareonthaitawee P., Cerqueira M.D., deKemp R.A., DePuey E.G., Dilsizian V., et al. SNMMI Cardiovascular Council Board of Directors; ASNC Board of Directors. Clinical Quantification of Myocardial Blood Flow Using PET: Joint Position Paper of the SNMMI Cardiovascular Council and the ASNC. J. Nucl. Med. 2018;59:273–293. doi: 10.2967/jnumed.117.201368. - DOI - PubMed
-
- Slomka P.J., Alexanderson E., Jácome R., Jiménez M., Romero E., Meave A., Le Meunier L., Dalhbom M., Berman D.S., Germano G., et al. Comparison of clinical tools for measurements of regional stress and rest myocardial blood flow assessed with 13N-ammonia PET/CT. J. Nucl. Med. 2012;53:171–181. doi: 10.2967/jnumed.111.095398. - DOI - PubMed
-
- Giubbini R., Bertoli M., Durmo R., Bonacina M., Peli A., Faggiano I., Albano D., Milan E., Stern E., Paghera B., et al. Comparison between N13NH3-PET and 99mTc-Tetrofosmin-CZT SPECT in the evaluation of absolute myocardial blood flow and flow reserve. J. Nucl. Cardiol. 2021;28:1906–1918. doi: 10.1007/s12350-019-01939-x. - DOI - PubMed
-
- Agostini D., Roule V., Nganoa C., Roth N., Baavour R., Parienti J.J., Beygui F., Manrique A. First validation of myocardial flow reserve assessed by dynamic 99mTc-sestamibi CZT-SPECT camera: Head to head comparison with 15O-water PET and fractional flow reserve in patients with suspected coronary artery disease. The WATERDAY study. Eur. J. Nucl. Med. Mol. Imaging. 2018;45:1079–1090. doi: 10.1007/s00259-018-3958-7. - DOI - PMC - PubMed
LinkOut - more resources
Full Text Sources
Miscellaneous