. 2024 May;238(5):471-482.
doi: 10.1177/09544119241244537. Epub 2024 Apr 21.

A novel design of hip-stem with reduced strain-shielding

Affiliations

A novel design of hip-stem with reduced strain-shielding

Tanmoy Loha et al. Proc Inst Mech Eng H. 2024 May.

Abstract

The use of uncemented stems in hip arthroplasty has been increasing, even in osteoporotic patients. The major concerns of uncemented hip-stems, however, are peri-prosthetic fracture, thigh pain, and proximal femoral stress-/strain-shielding. In this study, a novel design of uncemented hip-stem is proposed that will reduce such concerns, improve osseointegration, and benefit both osteoporotic and arthritic patients. The stem has a central titanium alloy core surrounded by a set of radial buttresses that are partly porous titanium, as is the stem tip. The aim of the study was to investigate the mechanical behaviour of the proposed partly-porous design, examining load transfer in the short-term, and comparing its strain-shielding behaviour with a solid metal implant. The long-term effect of implant-induced bone remodelling was also simulated. Computed tomography based three-dimensional finite element models of an intact proximal femur, and the same femur implanted with the proposed design, were developed. Peak hip contact and major muscle forces corresponding to level-walking and stair climbing were applied. The proposed partly-porous design had approximately 50% lower strain-shielding than the solid-metal counterpart. Results of bone remodelling simulation indicated that only 16% of the total bone volume is subjected to reduction of bone density. Strain concentrations were observed in the bone around the stem-tip for both solid and porous implants; however, it was less prominent for the porous design. Lower strain-shielding and reduced bone resorption are advantageous for long-term fixation, and the reduced strain concentration around the stem-tip indicates a lower risk of peri-prosthetic fracture.

Keywords: Femur; fixation stem; hip prosthesis; osteoporosis; porous material; stress-shielding.