. 2024 Jun:327:114944.
doi: 10.1016/j.jviromet.2024.114944. Epub 2024 Apr 20.

Heparin-mediated PCR interference in SARS-CoV-2 assays and subsequent reversal with heparinase I

Affiliations

Heparin-mediated PCR interference in SARS-CoV-2 assays and subsequent reversal with heparinase I

K Edwards et al. J Virol Methods. 2024 Jun.

Abstract

Heparin is postulated to block the interaction of SARS-CoV-2 with highly glycosylated proteins which are critical for binding the angiotensin-converting enzyme 2 (ACE2), an essential mechanism for host-cell entry and viral replication. Intranasal heparin is under investigation for use as a SARS-CoV-2 preventative in the IntraNasal Heparin Trial (INHERIT, NCT05204550). Heparin directly interferes with real-time quantitative polymerase chain reaction (RT-qPCR), the gold standard for SARS-CoV-2 detection. This study aimed to investigate the magnitude of heparin interference across various clinical laboratory testing platforms, and the reversal of any interference by degradation of heparin using the heparinase I enzyme in nasopharyngeal swab (NP) samples for SARS-CoV-2 analysis by RT-qPCR. Heparin-mediated PCR interference was evident at heparin concentrations as low as 10 IU/mL across all platforms tested, with the exclusion of the Hologic Panther Aptima SARS-CoV-2 assay. Rates of false negative or invalid results increased with increasing heparin concentrations on all platforms, except the Hologic Panther Aptima and Roche Cobas LIAT. Heparinase I reversed heparin-mediated PCR inhibition across in all samples tested, except those with initial Ct values >35. Our study shows that the use of heparin-containing nasal sprays interferes with the detection of SARS-CoV-2 in NP swab samples by RT-qPCR, a phenomenon that is not well recognised in the literature. Furthermore, this study has also demonstrated that heparin-mediated PCR inhibition can be prevented through heparinase I treatment, demonstrating restoration of clinically significant results with Ct values <35.

Keywords: Heparin; Heparinase I; INHERIT; Intranasal heparin trial; PCR interference; SARS-CoV-2.

PubMed Disclaimer

Conflict of interest statement

Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

References

Publication types

Associated data