Purpose of review: Heart failure (HF) is a major public health problem worldwide, affecting more than 64 million people [1]. The complex and severe nature of HF presents challenges in providing cost-effective care as patients often require multiple hospitalizations and treatments. This review of relevant studies with focus on the last 10 years summarizes the health and economic implications of various HF treatment options in Europe and beyond. Although the main cost drivers in HF treatment are clinical (re)admission and decompensation of HF, an assessment of the economic impacts of various other device therapy options for HF care are included in this review. This includes: cardiovascular implantable electronic devices (CIEDs) such as cardiac-resynchronisation-therapy devices that include pacemaking (CRT-P), cardiac-resynchronisation-therapy devices that include defibrillation (CRT-D), implantable cardioverter/defibrillators (ICDs) and various types of pacemakers. The impact of (semi)automated (tele)monitoring as a relevant factor for increasing both the quality and economic impact of care is also taken into consideration. Quality of life adjusted life years (QALYs) are used in the overall context as a composite metric reflecting quantity and quality of life as a standardized measurement of incremental cost-effectiveness ratios (ICER) of different device-based HF interventions.
Recent findings: In terms of the total cost of different devices, CRT-Ds were found in several studies to be more expensive than all other devices in regards to runtime and maintenance costs including (re)implantation. In the case of CRT combined with an implantable cardioverter-defibrillator (CRT-D) versus ICD alone, CRT-D was found to be the most cost-effective treatment in research work over the past 10 years. Further comparison between CRT-D vs. CRT-P does not show an economic advantage of CRT-D as a minority of patients require shock therapy. Furthermore, a positive health economic effect and higher survival rate is seen in CRT-P full ventricular stimulation vs. right heart only stimulation. Telemedical care has been found to provide a positive health economic impact for selected patient groups-even reducing patient mortality. For heart failure both in ICD and CRT-D subgroups the given telemonitoring benefit seems to be greater in higher-risk populations with a worse HF prognosis. In patients with HF, all CIED therapies are in the range of commonly accepted cost-effectiveness. QALY and ICER calculations provide a more nuanced understanding of the economic impact these therapies create in the healthcare landscape. For severe cases of HF, CRT-D with telemedical care seems to be the better option from a health economic standpoint, as therapy is more expensive, but costs per QALY range below the commonly accepted threshold.
Keywords: Device-based therapy; Health economic effects; Heart failure; Telemonitoring.
© 2024. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.
Similar articles
-
Economic Value and Cost-Effectiveness of Cardiac Resynchronization Therapy Among Patients With Mild Heart Failure: Projections From the REVERSE Long-Term Follow-Up.JACC Heart Fail. 2017 Mar;5(3):204-212. doi: 10.1016/j.jchf.2016.10.014. Epub 2017 Jan 11. JACC Heart Fail. 2017. PMID: 28254126
-
Remote Monitoring of Implantable Cardioverter-Defibrillators, Cardiac Resynchronization Therapy and Permanent Pacemakers: A Health Technology Assessment.Ont Health Technol Assess Ser. 2018 Oct 24;18(7):1-199. eCollection 2018. Ont Health Technol Assess Ser. 2018. PMID: 30443279 Free PMC article. Review.
-
Cost-Effectiveness of Adding Cardiac Resynchronization Therapy to an Implantable Cardioverter-Defibrillator Among Patients With Mild Heart Failure.Ann Intern Med. 2015 Sep 15;163(6):417-26. doi: 10.7326/M14-1804. Ann Intern Med. 2015. PMID: 26301323 Free PMC article.
-
Cost-effectiveness of implantable cardiac devices in patients with systolic heart failure.Heart. 2016 Nov 1;102(21):1742-1749. doi: 10.1136/heartjnl-2015-308883. Epub 2016 Jul 13. Heart. 2016. PMID: 27411837 Free PMC article.
-
A review of economic evaluation models for cardiac resynchronization therapy with implantable cardioverter defibrillators in patients with heart failure.Eur J Health Econ. 2016 Dec;17(9):1159-1172. doi: 10.1007/s10198-015-0752-3. Epub 2016 Jan 4. Eur J Health Econ. 2016. PMID: 26728985 Free PMC article. Review.
References
-
- GBD. Global, regional, and national incidence, prevalence, and years lived with disability for 354 diseases and injuries for 195 countries and territories, 1990–2017: a systematic analysis for the Global Burden of Disease Study 2017. Lancet. 2017;392:1789–858.
-
- Hobbs FD, Roalfe AK, Davis RC, Davies MK, Hare R. the Midlands Research Practices Consortium (MidReC). Prognosis of all-cause heart failure and borderline left ventricu- lar systolic dysfunction: 5 year mortality follow-up of the Echocardiographic Heart of England Screening Study (ECHOES). Eur Heart J. 2007;28:1128–34. - DOI - PubMed
-
- Maggioni AP, Dahlström U, Filippatos G, Chioncel O, Leiro MC, Drozdz J, ... Heart Failure Association of the ESC (HFA) (2010) EURObservational research programme: the heart failure pilot survey (ESC‐HF Pilot). Europe J Heart Fail 12(10):1076–1084
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials
Miscellaneous