Fluid balance versus weighing: A comparison in ICU patients: A single center observational study
- PMID: 38669249
- PMCID: PMC11051658
- DOI: 10.1371/journal.pone.0299474
Fluid balance versus weighing: A comparison in ICU patients: A single center observational study
Abstract
Background: The fluid balance is a critical parameter in intensive care units (ICU) as it provides information about the patient's volume status. However, the accuracy of fluid balance measurements is often compromised due to the complexity and repetition of actions involved. Additionally, the fluid balance could be recalculated for insensible fluid loss. Weighing is an alternative method to estimate the patient's volume status. Built-in scales in beds make patient weighing easier and less time-consuming, allowing clinicians to intervene more quickly on existing treatments.
Aim: This study compares fluid balance, and body weight changes over time in ICU patients. Furthermore, it seeks to determine the degree of congruence between the fluid balance corrected for insensible fluid loss and daily body weight in ICU patients.
Methods: A single-center observational study was conducted in an ICU of a university hospital. All consecutive patients admitted to a bed with an integrated weighing scale were eligible. Exclusion criteria were (1) body weight ≥254,4 kilograms; (2) oral nutrition; (3) a flush catheter or balance; (4) only a single weight measurement; (5) delta body weight change of ≥5kg in 12 hours. Weights and fluid balances were obtained every 12 hours.
Results: We obtained 2282 measurements (n = 187 patients). The correlation between weight and fluid balance was weak (r = 0.274). After adjusting the fluid balance for insensible fluid loss, the correlation remained weak (r = 0,268). Bland Altman analysis revealed a wide confidence interval for both the fluid balance and corrected fluid balance versus weight.
Conclusion and implications of key findings: This study shows a weak correlation between weight and fluid balance. Therefore, when monitoring the volume status in the ICU, fluid balance and weight should both be taken into account. This two-pronged approach is crucial because it provides more control over erroneous fluid balance or weighing measurements.
Copyright: © 2024 Mensink et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Conflict of interest statement
The authors have declared that no competing interests exist.
Figures



Similar articles
-
Electronic bed weighing vs daily fluid balance changes after cardiac surgery.J Crit Care. 2013 Dec;28(6):1113.e1-5. doi: 10.1016/j.jcrc.2013.07.056. Epub 2013 Oct 18. J Crit Care. 2013. PMID: 24144961
-
Estimation of fluid status changes in critically ill patients: fluid balance chart or electronic bed weight?J Crit Care. 2012 Dec;27(6):745.e7-12. doi: 10.1016/j.jcrc.2011.12.017. Epub 2012 Feb 14. J Crit Care. 2012. PMID: 22341728
-
Cumulative changes in weight but not fluid volume balances reflect fluid accumulation in ICU patients.Acta Anaesthesiol Scand. 2017 Feb;61(2):205-215. doi: 10.1111/aas.12840. Epub 2016 Nov 30. Acta Anaesthesiol Scand. 2017. PMID: 27900767
-
Estimation of Body Fluid Status by Fluid Balance and Body Weight in Critically Ill Adult Patients: A Systematic Review.Worldviews Evid Based Nurs. 2019 Dec;16(6):470-477. doi: 10.1111/wvn.12394. Worldviews Evid Based Nurs. 2019. PMID: 31811748
-
Bioelectrical impedance analysis during deresuscitation: correlation and agreement with cumulative fluid balance in ICU patients.J Clin Monit Comput. 2023 Apr;37(2):679-687. doi: 10.1007/s10877-022-00923-0. Epub 2022 Oct 5. J Clin Monit Comput. 2023. PMID: 36197549 Review.
Cited by
-
Subcutaneous edema segmentation on abdominal CT using multi-class labels and iterative annotation.Int J Comput Assist Radiol Surg. 2025 Jan;20(1):89-95. doi: 10.1007/s11548-024-03262-4. Epub 2024 Sep 14. Int J Comput Assist Radiol Surg. 2025. PMID: 39271574 Free PMC article.
References
-
- Davies H, Leslie G, Morgan D. Effectiveness of daily fluid balance charting in comparison to the measurement of body weight when used in guiding fluid therapy for critically ill adult patients: a systematic review protocol. JBI Database System Rev Implement Rep. 2015. Mar;13(3):111–23. doi: 10.11124/jbisrir-2015-2010 - DOI - PubMed
-
- Malbrain MLNG, Marik PE, Witters I, Cordemans C, Kirkpatrick AW, Roberts DJ, et al.. Fluid overload, de-resuscitation, and outcomes in critically ill or injured patients: a systematic review with suggestions for clinical practice. Anestezjol Intens Ter. 2014. Nov 28;46(5):361–80. doi: 10.5603/AIT.2014.0060 - DOI - PubMed
-
- Neplenbroek L, VS de K, GM de J. De illusie van de vochtbalans. Nederlands T,ijdschrift voor de Heelkunde. 2022;31(4):37–41.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials