Inversion recovery and saturation recovery pulmonary vein MR angiography using an image based navigator fluoro trigger and variable-density 3D cartesian sampling with spiral-like order
- PMID: 38676848
- DOI: 10.1007/s10554-024-03111-0
Inversion recovery and saturation recovery pulmonary vein MR angiography using an image based navigator fluoro trigger and variable-density 3D cartesian sampling with spiral-like order
Abstract
Contrast enhanced pulmonary vein magnetic resonance angiography (PV CE-MRA) has value in atrial ablation pre-procedural planning. We aimed to provide high fidelity, ECG gated PV CE-MRA accelerated by variable density Cartesian sampling (VD-CASPR) with image navigator (iNAV) respiratory motion correction acquired in under 4 min. We describe its use in part during the global iodinated contrast shortage. VD-CASPR/iNAV framework was applied to ECG-gated inversion and saturation recovery gradient recalled echo PV CE-MRA in 65 patients (66 exams) using .15 mmol/kg Gadobutrol. Image quality was assessed by three physicians, and anatomical segmentation quality by two technologists. Left atrial SNR and left atrial/myocardial CNR were measured. 12 patients had CTA within 6 months of MRA. Two readers assessed PV ostial measurements versus CTA for intermodality/interobserver agreement. Inter-rater/intermodality reliability, reproducibility of ostial measurements, SNR/CNR, image, and anatomical segmentation quality was compared. The mean acquisition time was 3.58 ± 0.60 min. Of 35 PV pre-ablation datasets (34 patients), mean anatomical segmentation quality score was 3.66 ± 0.54 and 3.63 ± 0.55 as rated by technologists 1 and 2, respectively (p = 0.7113). Good/excellent anatomical segmentation quality (grade 3/4) was seen in 97% of exams. Each rated one exam as moderate quality (grade 2). 95% received a majority image quality score of good/excellent by three physicians. Ostial PV measurements correlated moderate to excellently with CTA (ICCs range 0.52-0.86). No difference in SNR was observed between IR and SR. High quality PV CE-MRA is possible in under 4 min using iNAV bolus timing/motion correction and VD-CASPR.
Keywords: Atrial fibrillation; Image based navigators; Left atrial delayed enhancement; Magnetic resonance angiography; Variable density cartesian sampling.
© 2024. The Author(s), under exclusive licence to Springer Nature B.V.
Similar articles
-
Radial-based acquisition strategies for pre-procedural non-contrast cardiovascular magnetic resonance angiography of the pulmonary veins.J Cardiovasc Magn Reson. 2020 Nov 30;22(1):78. doi: 10.1186/s12968-020-00685-1. J Cardiovasc Magn Reson. 2020. PMID: 33256791 Free PMC article.
-
Feasibility study of electrocardiographic and respiratory gated, gadolinium enhanced magnetic resonance angiography of pulmonary veins and the impact of heart rate and rhythm on study quality.J Cardiovasc Magn Reson. 2014 Jun 19;16(1):43. doi: 10.1186/1532-429X-16-43. J Cardiovasc Magn Reson. 2014. PMID: 24947763 Free PMC article.
-
Validation of contrast-enhanced time-resolved magnetic resonance angiography in pre-ablation planning in patients with atrial fibrillation: comparison with traditional technique.Int J Cardiovasc Imaging. 2018 Sep;34(9):1451-1458. doi: 10.1007/s10554-018-1355-8. Epub 2018 Apr 16. Int J Cardiovasc Imaging. 2018. PMID: 29663178 Free PMC article.
-
Accelerated free breathing ECG triggered contrast enhanced pulmonary vein magnetic resonance angiography using compressed sensing.J Cardiovasc Magn Reson. 2014 Nov 22;16(1):91. doi: 10.1186/s12968-014-0091-z. J Cardiovasc Magn Reson. 2014. PMID: 25416082 Free PMC article.
-
ECG-gated imaging of the left atrium and pulmonary veins: Intra-individual comparison of CTA and MRA.Clin Radiol. 2013 Oct;68(10):1059-64. doi: 10.1016/j.crad.2013.05.006. Epub 2013 Jun 25. Clin Radiol. 2013. PMID: 23809271
Cited by
-
Isotropic, high-resolution, whole-chest inversion recovery contrast-enhanced magnetic resonance angiography in under 4.5 min using image-based navigator fluoro trigger.Front Cardiovasc Med. 2025 Apr 30;12:1549275. doi: 10.3389/fcvm.2025.1549275. eCollection 2025. Front Cardiovasc Med. 2025. PMID: 40371067 Free PMC article.
References
-
- Amukotuwa SA, Bammer R, Jackson DM, Sutherland T (2022) Iodinated contrast media shortage: insights and guidance from two major public hospitals. J Med Imaging Radiat Oncol 66:946–956. https://doi.org/10.1111/1754-9485.13444 - DOI - PubMed - PMC
-
- Dong J, Dickfeld T, Dalal D, Cheema A, Vasamreddy CR, Henrikson CA, Marine JE et al (2006) Initial experience in the use of integrated electroanatomic mapping with three-dimensional MR/CT images to guide catheter ablation of atrial fibrillation. J Cardiovasc Electrophysiol 17:459–466. https://doi.org/10.1111/j.1540-8167.2006.00425.x - DOI - PubMed
-
- Sheffer D, Kholmovski E, Chang L, Velagapudi KN, Damal K, Marrouche NF, McGann C (2013) Improved left atrial imaging in atrial fibrillation patients using novel ECG-gated vs. conventional non-gated cardiac MRA. J Cardiovasc Magn Reson 15:O50. https://doi.org/10.1186/1532-429X-15-S1-O50 - DOI - PMC
-
- Hu P, Peters DC, Stoeck C, Kissinger KV, Goddu B, Goepfert L, Manning WJ et al (2009) Off-resonant pulmonary vein imaging. J Cardiovasc Magn Reson. https://doi.org/10.1186/1532-429X-11-S1-P185 - DOI - PMC
-
- Rashid I, Ginami G, Nordio G, Fotaki A, Neji R, Alam H, Pushparajah K, Frigiola A, Valverde I, Botnar RM, Prieto C (2023) Magnetization transfer BOOST noncontrast angiography improves pulmonary vein imaging in adults with congenital heart disease. J Magn Reson Imaging 57(2):521–531. https://doi.org/10.1002/jmri.28280 - DOI - PubMed
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Research Materials