Ratiometric Sensing of Azithromycin and Sulfide Using Dual Emissive Carbon Dots: A Turn On-Off-On Approach
- PMID: 38691279
- DOI: 10.1007/s10895-024-03737-2
Ratiometric Sensing of Azithromycin and Sulfide Using Dual Emissive Carbon Dots: A Turn On-Off-On Approach
Abstract
A novel ratiometric fluorescence probe was developed for the determination of azithromycin (AZM) and sulfide ions based on the differential modulation of red emissive carbon dots (R-N@CDs) and blue emissive carbon dots (B-NS@CDs). The addition of sulfide anion selectively quenched the red emission of R-N@CDs while the blue emission of B-NS@CDs unaffected. Upon subsequent introduction of AZM to this R-N@CDs@sulfide system, the quenched red fluorescence was restored. Comprehensive characterization of the CDs was performed using UV-Vis, fluorescence, FTIR spectroscopy, XPS, and TEM. The proposed method exhibited excellent sensitivity and selectivity, with limits of detection of 0.33 µM for AZM and 0.21 µM for sulfide. Notably, this approach enabled direct detection of sulfide without requiring prior modulation of the CDs with metal ions, as is common in other reported methods. The ratiometric probe was successfully applied for the determination of AZM in biological fluids and sulfide in environmental water samples with high selectivity. This work presents the first fluorometric method for the detection of AZM in biological fluids.
Keywords: Azithromycin; Biological fluids; Carbon dots; Ratiometric; Sulfide.
© 2024. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.
Conflict of interest statement
Declarations. Ethical Approval: The pharmacokinetic study was conducted in full compliance with ethical regulations, under a protocol approved by the Institutional Animal Care and Use Committee at Assiut University (02/2024/0095). The experiment adhered to the guiding principles in the Helsinki Declaration for humane treatment of animals. Consent to Participate: Not applicable. Consent for publication: Not Applicable. Competing Interests: The authors declare no competing interests.
Similar articles
-
Nitrogen- and Sulfur-Codoped Carbon Dots for Highly Selective and Sensitive Fluorescent Detection of Hg2+ Ions and Sulfide in Environmental Water Samples.J Agric Food Chem. 2019 Mar 13;67(10):2794-2800. doi: 10.1021/acs.jafc.8b07176. Epub 2019 Mar 4. J Agric Food Chem. 2019. PMID: 30789264
-
On-Off-On Fluorometric Detection of Hg(II) and L-Cysteine Using Red Emissive Nitrogen-Doped Carbon Dots for Environmental and Clinical Sample Analysis.J Fluoresc. 2025 Feb;35(2):1139-1150. doi: 10.1007/s10895-024-03598-9. Epub 2024 Feb 1. J Fluoresc. 2025. PMID: 38300484
-
Carrot-derived carbon dots modified with polyethyleneimine and nile blue for ratiometric two-photon fluorescence turn-on sensing of sulfide anion in biological fluids.Talanta. 2017 Jul 1;169:141-148. doi: 10.1016/j.talanta.2017.03.083. Epub 2017 Mar 28. Talanta. 2017. PMID: 28411804
-
A dual-emission ratiometric fluorescent biosensor for ultrasensitive detection of glibenclamide using S-CDs/CdS quantum dots.Spectrochim Acta A Mol Biomol Spectrosc. 2023 Sep 5;297:122714. doi: 10.1016/j.saa.2023.122714. Epub 2023 Apr 6. Spectrochim Acta A Mol Biomol Spectrosc. 2023. PMID: 37080048
-
Construction of FRET-based CDs@RBH Ratiometric Fluorescent Probe for Cu2+ Sensing.J Fluoresc. 2025 Jun 14. doi: 10.1007/s10895-025-04398-5. Online ahead of print. J Fluoresc. 2025. PMID: 40516017 Review.
Cited by
-
Smart fluorometric sensing of metal contaminants in canned foods: a carbon dot-based dual-response system for quantifying aluminum and cobalt ions.RSC Adv. 2025 Mar 4;15(9):6962-6973. doi: 10.1039/d5ra00448a. eCollection 2025 Feb 26. RSC Adv. 2025. PMID: 40041372 Free PMC article.
-
A novel urease-assisted ratiometric fluorescence sensing platform based on pH-modulated copper-quenched near-infrared carbon dots and methyl red-quenched red carbon dots for selective urea monitoring.Mikrochim Acta. 2024 Aug 4;191(8):505. doi: 10.1007/s00604-024-06573-0. Mikrochim Acta. 2024. PMID: 39097544
References
-
- Wilms EB, Touw DJ, Heijerman HGM (2006) Pharmacokinetics of azithromycin in plasma, blood, Polymorphonuclear neutrophils and Sputum during Long-Term Therapy in patients with cystic fibrosis. Ther Drug Monit 28(2). https://doi.org/10.1097/01.ftd.0000195617.69721.a5
-
- Liu P, Allaudeen H, Chandra R, Phillips K, Jungnik A, Breen Jeanne D, Sharma A (2007) Comparative pharmacokinetics of azithromycin in serum and White Blood cells of healthy subjects receiving a single-dose extended-release regimen versus a 3-Day Immediate-Release Regimen. Antimicrob Agents Chemother 51(1):103–109. https://doi.org/10.1128/aac.00852-06 - DOI - PubMed
-
- Lalak NJ, Morris DL (1993) Azithromycin Clinical Pharmacokinetics. Clin Pharmacokinet 25(5):370–374. https://doi.org/10.2165/00003088-199325050-00003 - DOI - PubMed
-
- Olupot-Olupot P, Okiror W, Mnjalla H, Muhindo R, Uyoga S, Mpoya A, Williams T, terHeine R, Burger D, Urban B, Connon R, George E, Gibb D, Walker A, Maitland K (2023) Pharmacokinetics and pharmacodynamics of azithromycin in severe malaria bacterial co-infection in African children (TABS-PKPD): a protocol for a phase II randomised controlled trial [version 2; peer review: 2 approved]. 6(161). https://doi.org/10.12688/wellcomeopenres.16968.2
-
- Azithromycin (2016) In: Aronson JK (ed) Meyler’s Side effects of drugs (Sixteenth Edition). Elsevier, Oxford, pp 785–793. doi: https://doi.org/10.1016/B978-0-444-53717-1.00345-0 - DOI
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Miscellaneous