. 2024 Jul 1:281:114574.
doi: 10.1016/j.physbeh.2024.114574. Epub 2024 Apr 30.

Functional near-infrared spectroscopy based blood pressure variations and hemodynamic activity of brain monitoring following postural changes: A systematic review

Affiliations

Functional near-infrared spectroscopy based blood pressure variations and hemodynamic activity of brain monitoring following postural changes: A systematic review

Roya Kheyrkhah Shali et al. Physiol Behav. .

Abstract

Postural change from supine or sitting to standing up leads to displacement of 300 to 1000 mL of blood from the central parts of the body to the lower limb, which causes a decrease in venous return to the heart, hence decrease in cardiac output, causing a drop in blood pressure. This may lead to falling down, syncope, and in general reducing the quality of daily activities, especially in the elderly and anyone suffering from nervous system disorders such as Parkinson's or orthostatic hypotension (OH). Among different modalities to study brain function, functional near-infrared spectroscopy (fNIRS) is a neuroimaging method that optically measures the hemodynamic response in brain tissue. Concentration changes in oxygenated hemoglobin (HbO2) and deoxygenated hemoglobin (HHb) are associated with brain neural activity. fNIRS is significantly more tolerant to motion artifacts compared to fMRI, PET, and EEG. At the same time, it is portable, has a simple structure and usage, is safer, and much more economical. In this article, we systematically reviewed the literature to examine the history of using fNIRS in monitoring brain oxygenation changes caused by sudden changes in body position and its relationship with the blood pressure changes. First, the theory behind brain hemodynamics monitoring using fNIRS and its advantages and disadvantages are presented. Then, a study of blood pressure variations as a result of postural changes using fNIRS is described. It is observed that only 58 % of the references concluded a positive correlation between brain oxygenation changes and blood pressure changes. At the same time, 3 % showed a negative correlation, and 39 % did not show any correlation between them.

Keywords: Blood pressure; Correlation; NIRS; Postural change; Regression.

PubMed Disclaimer

Conflict of interest statement

Declaration of competing interest The authors declare no competing financial interests.