Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2024 Jun:36:101867.
doi: 10.1016/j.nuclcard.2024.101867. Epub 2024 Apr 30.

A novel method combining gated SPECT and vectorcardiography to guide left ventricular lead placement to improve response to cardiac resynchronization therapy: A proof of concept study

Affiliations

A novel method combining gated SPECT and vectorcardiography to guide left ventricular lead placement to improve response to cardiac resynchronization therapy: A proof of concept study

Hongjin Si et al. J Nucl Cardiol. 2024 Jun.

Abstract

Background: The segment of the latest mechanical contraction (LMC) does not always overlap with the site of the latest electrical activation (LEA). By integrating both mechanical and electrical dyssynchrony, this proof-of-concept study aimed to propose a new method for recommending left ventricular (LV) lead placements, with the goal of enhancing response to cardiac resynchronization therapy (CRT).

Methods: The LMC segment was determined by single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI) phase analysis. The LEA site was detected by vectorcardiogram. The recommended segments for LV lead placement were as follows: (1) the LMC viable segments that overlapped with the LEA site; (2) the LMC viable segments adjacent to the LEA site; (3) If no segment met either of the above, the LV lateral wall was recommended. The response was defined as ≥15% reduction in left ventricular end-systolic volume (LVESV) 6-months after CRT. Patients with LV lead located in the recommended site were assigned to the recommended group, and those located in the non-recommended site were assigned to the non-recommended group.

Results: The cohort comprised of 76 patients, including 54 (71.1%) in the recommended group and 22 (28.9%) in the non-recommended group. Among the recommended group, 74.1% of the patients responded to CRT, while 36.4% in the non-recommended group were responders (P = .002). Compared to pacing at the non-recommended segments, pacing at the recommended segments showed an independent association with an increased response by univariate and multivariable analysis (odds ratio 5.00, 95% confidence interval 1.73-14.44, P = .003; odds ratio 7.33, 95% confidence interval 1.53-35.14, P = .013). Kaplan-Meier curves showed that pacing at the recommended LV lead position demonstrated a better long-term prognosis.

Conclusion: Our findings indicate that pacing at the recommended segments, by integrating of mechanical and electrical dyssynchrony, is significantly associated with an improved CRT response and better long-term prognosis.

Keywords: Cardiac resynchronization therapy; Electrical activation; Mechanical contraction; SPECT MPI; Vectorcardiogram.