Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2024 Oct:67:96-102.
doi: 10.1016/j.carrev.2024.04.296. Epub 2024 Apr 25.

Combined use of intra-aortic balloon pump and impella in cardiogenic shock: A systematic review

Affiliations
Free article

Combined use of intra-aortic balloon pump and impella in cardiogenic shock: A systematic review

Jacopo Farina et al. Cardiovasc Revasc Med. 2024 Oct.
Free article

Abstract

Background: Use of Intra-Aortic Balloon Pump (IABP) in combination with Impella has been described as an alternative strategy for mechanical circulatory support (MCS) in patients with cardiogenic shock (CS). We provide a systematic review aimed to explore the effectiveness of this paired MCS approach.

Methods: We conducted a comprehensive systematic search in MEDLINE, Scopus, and Cochrane databases to identify all studies that investigated dual MCS with IABP and Impella.

Results: Our search strategy identified 12 articles, including 1 randomized controlled trial, 1 retrospective study, 1 case series, 7 case report and 2 animal studies. Rationale for this combined MCS strategy stems from an observed reduction in myocardial oxygen demand/supply ratio compared to the use of each device alone, without determining significant variations in left ventricular work. Nonetheless, this combined approach also leads to a 30-40 % decline in Impella flow, increasing the risk of bleeding, Impella displacement, as well as triggering positioning and pressure alarms. Additionally, hemolytic risk data yielded inconclusive results. Importantly, there were no notable disparities in mortality rates when comparing the combined strategy to the use of each device individually.

Conclusion: At the current state-of-the-art, there are no conclusive data demonstrating net clinical benefits of combining Impella with IABP. Considering the substantial risks of morbidity associated, we recommend against its use in clinical practice.

Keywords: Cardiogenic shock; Dual mechanical circulatory support; Impella; Intra-aortic balloon pump.

PubMed Disclaimer

Conflict of interest statement

Declaration of competing interest The authors declare the following financial interests/personal relationships which may be considered as potential competing interests: Jacopo Farina reports administrative support was provided by University Hospital Arcispedale Sant'Anna of Ferrara Department of Cardiology. If there are other authors, they declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Publication types

LinkOut - more resources