Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2024 Jul;19(7):1281-1284.
doi: 10.1007/s11548-024-03150-x. Epub 2024 May 5.

Cognitive load in tele-robotic surgery: a comparison of eye tracker designs

Affiliations
Comparative Study

Cognitive load in tele-robotic surgery: a comparison of eye tracker designs

Roger D Soberanis-Mukul et al. Int J Comput Assist Radiol Surg. 2024 Jul.

Abstract

Purpose: Eye gaze tracking and pupillometry are evolving areas within the field of tele-robotic surgery, particularly in the context of estimating cognitive load (CL). However, this is a recent field, and current solutions for gaze and pupil tracking in robotic surgery require assessment. Considering the necessity of stable pupillometry signals for reliable cognitive load estimation, we compare the accuracy of three eye trackers, including head and console-mounted designs.

Methods: We conducted a user study with the da Vinci Research Kit (dVRK), to compare the three designs. We collected eye tracking and dVRK video data while participants observed nine markers distributed over the dVRK screen. We compute and analyze pupil detection stability and gaze prediction accuracy for the three designs.

Results: Head-worn devices present better stability and accuracy of gaze prediction and pupil detection compared to console-mounted systems. Tracking stability along the field of view varies between trackers, with gaze predictions detected at invalid zones of the image with high confidence.

Conclusion: While head-worn solutions show benefits in confidence and stability, our results demonstrate the need to improve eye tacker performance regarding pupil detection, stability, and gaze accuracy in tele-robotic scenarios.

Keywords: Cognitive load; Eye gaze tracking; Pupillometry; Tele-robotic surgery.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Sridhar AN, Briggs TP, Kelly JD, Nathan S (2017) Training in robotic surgery—an overview. Curr Urol Rep. https://doi.org/10.1007/s11934-017-0710-y
    1. Ruiz Puentes P, Soberanis-Mukul RD, Acar A, Gupta I, Bhowmick J, Li Y, Ghazi A, Kazanzides P, Ying Wu J, Unberath M (2023) Pupillometry in telerobotic surgery: A comparative evaluation of algorithms for cognitive effort estimation. Med Robot. https://doi.org/10.54844/mr.2023.0420
    1. Fujii K, Gras G, Salerno A, Yang G-Z (2018) Gaze gesture based human robot interaction for laparoscopic surgery. Med Image Anal 44:196–214. https://doi.org/10.1016/j.media.2017.11.011 - DOI - PubMed
    1. Niehorster DC, Santini T, Hessels RS, Hooge ITC, Kasneci E, Nyström M (2020) The impact of slippage on the data quality of head-worn eye trackers. Behav Res Methods 52(3):1140–1160. https://doi.org/10.3758/s13428-019-01307-0 - DOI - PubMed - PMC
    1. Krejtz K, Duchowski AT, Niedzielska A, Biele C, Krejtz I (2018) Eye tracking cognitive load using pupil diameter and microsaccades with fixed gaze. PLoS One 13(9):0203629 - DOI

Publication types

Grants and funding

LinkOut - more resources