Observational Study
. 2024 Aug 1;43(8):1031-1039.
doi: 10.1097/ICO.0000000000003560. Epub 2024 May 7.

Operating Room Waste Generated From Corneal and Conjunctival Surgeries

Affiliations
Observational Study

Operating Room Waste Generated From Corneal and Conjunctival Surgeries

Shambhawi Thakur et al. Cornea. .

Abstract

Purpose: The purposes of this study were to bring awareness to the surgical waste generated from corneal and conjunctival surgeries and to compare those findings with the waste generated from cataract surgeries.

Methods: This was an observational prospective pilot cohort study at a tertiary corneal/anterior segment private practice. All waste related to cataract, cornea, and conjunctival surgical procedures (including anesthesia waste and corneal tissue storage) was weighed. The primary outcome was total waste generated while other outcomes included surgical setting (ambulatory surgical center, hospital, and minor operating room) and comparison of corneal/conjunctival surgeries with cataract surgery.

Results: Surgical waste data were collected from 119 surgeries (82 corneal/conjunctival surgeries and 37 cataract surgeries). Hospital surgeries produced more waste than ambulatory surgical center and minor operating room surgeries. Penetrating keratoplasty (2.22 kg, P = 0.483) and Descemet stripping only (2.11 kg, P = 0.326) procedures generated comparable mean waste with cataract surgery (2.07 kg) while endothelial keratoplasties produced more ( P < 0.001, 0.002). (Deep) anterior lamellar keratoplasty results depended on the surgical setting. All conjunctival surgeries produced less waste than cataract surgery.

Conclusions: In comparison with cataract surgery, keratoplasties overall produced comparable or more waste while conjunctival surgeries produced less waste. The surgical setting and type of anesthesia played a substantial role in the amount of waste generated. Assessing waste production from different ophthalmic surgeries may increase awareness of the negative environmental impact of surgical waste and promote practice or legal changes to improve environmental sustainability.

PubMed Disclaimer

References

    1. Albert MG, Rothkopf DM. Operating room waste reduction in plastic and hand surgery. Plast Surg (Oakv). 2015;23:235–238.
    1. Kagoma YK, Stall N, Rubinstein E, et al. People, planet and profits: the case for greening operating rooms. CMAJ. 2012;184:1905–1911.
    1. Chang DF, Thiel CL. Ophthalmic Instrument Cleaning and Sterilization Task Force. Survey of cataract surgeons' and nurses' attitudes toward operating room waste. J Cataract Refract Surg. 2020;46:933–940.
    1. Chang DF. Needless waste and the sustainability of cataract surgery. Ophthalmology. 2020;127:1600–1602.
    1. Chang DF. Tackling the challenge of needless surgical waste in ophthalmology. J Cataract Refract Surg. 2023;49:333–338.

Publication types