Leg length determination by CT digital radiography
- PMID: 3871572
- DOI: 10.2214/ajr.144.3.613
Leg length determination by CT digital radiography
Abstract
CT digital radiography is a new accurate technique for measuring leg length discrepancy. It is easily performed on commercially available equipment with a radiation dose of 3-6 times less than the conventional technique. Because of the short time required to complete the examination, charges are comparable with those for existing procedures. Good correlation in total limb length measurements between this new technique and spot scanography was noted in 24 patients. CT digital radiography should be the preferred method for evaluation for limb length discrepancy, particularly in children, because of the simple technique and lowering of radiation dose.
Similar articles
-
[Limb length discrepancy determined by computerized tomography and radiography].Harefuah. 1989 May 10;116(10):515-6. Harefuah. 1989. PMID: 2792923 Hebrew.
-
Limb-length discrepancy measured with computerized axial tomographic equipment.J Bone Joint Surg Am. 1987 Jun;69(5):699-705. J Bone Joint Surg Am. 1987. PMID: 3597470
-
EOS low-dose radiography: a reliable and accurate upright assessment of lower-limb lengths.J Bone Joint Surg Am. 2013 Dec 4;95(23):e1831-7. doi: 10.2106/JBJS.L.00989. J Bone Joint Surg Am. 2013. PMID: 24306706
-
[Pelvic tilt and leg length discrepancy].Orthopade. 1990 Sep;19(5):244-62. Orthopade. 1990. PMID: 2234956 Review. German.
-
Clinical assessment and treatment of leg length inequalities.J Manipulative Physiol Ther. 1988 Aug;11(4):290-5. J Manipulative Physiol Ther. 1988. PMID: 3049890 Review.
Cited by
-
Length and angle measurements of the lower extremity in digital composite overview images.Eur Radiol. 2005 Jan;15(1):158-64. doi: 10.1007/s00330-004-2352-y. Epub 2004 May 26. Eur Radiol. 2005. PMID: 15164220
-
Three-dimensional measurements of the lower extremity in children and adolescents using a low-dose biplanar X-ray device.Eur Radiol. 2012 Apr;22(4):765-71. doi: 10.1007/s00330-011-2308-y. Epub 2011 Oct 20. Eur Radiol. 2012. PMID: 22011904
-
Methods for assessing leg length discrepancy.Clin Orthop Relat Res. 2008 Dec;466(12):2910-22. doi: 10.1007/s11999-008-0524-9. Epub 2008 Oct 4. Clin Orthop Relat Res. 2008. PMID: 18836788 Free PMC article.
-
Computed tomography for preoperative planning in total hip arthroplasty: what radiologists need to know.Skeletal Radiol. 2014 Aug;43(8):1041-51. doi: 10.1007/s00256-014-1853-2. Epub 2014 Mar 13. Skeletal Radiol. 2014. PMID: 24622927 Review.
-
Scanogram leg length measurement after total hip arthroplasty: not all landmarks are created equal.Skeletal Radiol. 2025 Sep;54(9):1897-1904. doi: 10.1007/s00256-025-04895-5. Epub 2025 Feb 19. Skeletal Radiol. 2025. PMID: 39969600 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical