Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2024 Dec 11;39(6):911-921.
doi: 10.11607/jomi.10843.

One-Piece CAD/CAM Abutment for Screw-Retained Single- Tooth Restorations: A 5-Year Prospective Cohort Study

One-Piece CAD/CAM Abutment for Screw-Retained Single- Tooth Restorations: A 5-Year Prospective Cohort Study

Andrea Parpaiola et al. Int J Oral Maxillofac Implants. .

Abstract

Purpose: To evaluate the clinical performance of implant-prosthetic rehabilitations carried out using ceramic-coated CAD/CAM titanium abutments.

Materials and methods: Thirty implants were placed in 30 patients and rehabilitated with 30 single crowns attached to CAD/CAM titanium abutments. A conventional procedure was applied, implants were placed after postextraction socket healing, and prosthetic restorations were placed after implant healing. Implant lengths ranged from 6 to 15 mm, and widths were 3.6, 4.2, and 4.8 mm. At the time of prosthesis delivery (T0), after 2 years (T1), and after 5 years (T2), the Plaque Index (PI), bleeding on probing (BoP), pocket probing depth (PPD), marginal bone level (MBL), and pink/white esthetic scores (PES/WES) were evaluated for each implant.

Results: No patient dropped out of the study during the follow-up period. All 30 implants were clinically successful 5 years after prosthesis delivery (survival rate: 100%) and showed no signs of peri-implant infection. Peri-implant soft tissues were in good health (BoP at T2: 0% in 73% of patients; 25% in 13% of patients; 50% in 10% of patients; and 75% in 3% of patients). The mean PPD was 2.05 ± 0.56 mm at T0, 1.992 ± 0.6 mm at T1, and 1.867 ± 0.439 mm at T2. The mean MBL was 0.413 ± 0.440 mm at T0, 0.306 ± 0.388 mm at T1, and 0.263 ± 0.368 mm at T2. The mean PES, WES, and PES/WES indices (7.43 ± 1.04, 7.57 ± 0.82, and 15.00 ± 1.17, respectively) indicate good integration of soft tissues, satisfactory esthetics, and overall positive outcomes.

Conclusions: The success rates, maintenance of MBLs, and periodontal and esthetic indices suggest the validity of implant-prosthetic rehabilitations with CAD/CAM abutments in cases of single crowns.

Keywords: Implant-prosthetic rehabilitation; CAD/CAM abutments; Single crowns; Clinical performance; Peri-implant soft tissues.

PubMed Disclaimer