Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2024 Sep;36(9).
doi: 10.25270/jic/24.00016.

Balloon venoplasty for right heart catheterization from the arm in patients with subclavian vein stenosis

Affiliations
Free article

Balloon venoplasty for right heart catheterization from the arm in patients with subclavian vein stenosis

Kishor Khanal et al. J Invasive Cardiol. 2024 Sep.
Free article

Abstract

Objectives: In the trans-radial era, arm venous access for right heart catheterization (RHC) is rising. Procedural success is affected by many factors, including subclavian/innominate vein stenosis (SVS) and pre-existing wires or catheters. In a study published previously by the same authors, 2% of cases had unsuccessful RHC through the arm, predominantly due to SVS. Since that study, techniques to improve RHC success rates have been developed, including crossing the stenosis with a coronary guidewire, followed by balloon dilatation. We aimed to determine whether subclavian/innominate venoplasty allows successful RHC in patients with SVS.

Methods: Our retrospective study included patients who had RHC from the arm between November 1, 2019, and December 31, 2022 that was unsuccessful due to the inability to pass a catheter through the SVS, and then underwent balloon venoplasty. The success rate of completed RHC was then assessed.

Results: Out of 2506 RHCs via arm access, 2488 were successful with a catheter alone or over a guidewire. In 18 patients, venoplasty was needed for catheter passage over a guidewire. Post-dilatation, all 18 cases (100%) had successful RHC with a mean procedural time of 35.2 (SD = 15.5) minutes. The most common stenosis site was the subclavian vein in 13 patients (72.2%), and 12 patients (66.7%) had pacemaker/ implantable cardioverter defibrillator wires present.

Conclusions: Balloon dilatation of SVS is an efficacious method to improve the success rate of RHC from the arm. It is a safe technique that may prevent cross-over to a different access site, thereby improving patient satisfaction and reducing the possibility of alternate site complications.

Keywords: cardiac catheterization; defibrillators; pacemaker; right heart catheterization; stenosis; venoplasty; venous access.