Omission of Antiplatelet Therapy in Patients With HeartMate 3 Left Ventricular Assist Devices: A Systematic Review and Meta-Analysis
- PMID: 38728742
- DOI: 10.1097/MAT.0000000000002225
Omission of Antiplatelet Therapy in Patients With HeartMate 3 Left Ventricular Assist Devices: A Systematic Review and Meta-Analysis
Abstract
The HeartMate 3 (HM3) left ventricular assist device has decreased thromboembolic events and minimized the risk of pump thrombosis. However, bleeding complications due to combined antithrombotic therapy with a vitamin K antagonist (VKA) and aspirin remain high. Only limited data on the safety of VKA monotherapy in HM3 patients are available. A systematic search on the main databases was performed. Observational data and randomized trials were eligible for this analysis. As primary endpoint, we analyzed hemocompatibility-related adverse events (HRAE). As secondary endpoints, we investigated the individual components of the primary endpoint. The analysis was carried out using the odds ratio (OR) as outcome measure. A random-effects model was fitted to the data. Five manuscripts fulfilled the inclusion criteria. These trials included 785 patients (381 on VKA monotherapy, 404 on VKA and aspirin). VKA monotherapy significantly reduced HRAE (OR: 0.11 [95% confidence interval {CI}: 0.02-0.59], p = 0.01, I2 = 87%). The reduction was driven by a decrease in bleeding complications (OR: 0.12 [95% CI: 0.02-0.62], p = 0.01, I2 = 86%) without increasing the rates of thromboembolic events (OR: 0.69 [95% CI: 0.26-1.81], p = 0.45, I = 0%). Vitamin K antagonist monotherapy is associated with a significant reduction of bleeding events without increasing the risk of thromboembolic complications in HM3 patients.
Copyright © ASAIO 2024.
Conflict of interest statement
Disclosure: T.S. received consulting/advisory fees from Medtronic Inc., Abbott Inc., BiVACOR, Berlin Heart, and CorWave; and received grant support from Medtronic Inc., Abbott Inc., Berlin Heart, and CorWave. D.W. is a proctor for Abbott Inc. and received consulting/advisory fees from Abbott Inc. and Xenios/Fresenius Medical Care. D.Z. is a proctor for and received speaker/consulting fees from Medtronic Inc., Abbott Inc., Berlin Heart, Edwards, Abiomed, and grant support from Medtronic Inc. and Abbott Inc. T.G. received speaker/consulting fees from AstraZeneca, Amgen, Bayer, Boehringer-Ingelheim, Bristol Myers Squibb, Daiichi- Sankyo, Novartis, and Pfizer, and grant support from Boehringer-Ingelheim, Bristol Myers Squibb, Medtronic and Abbott. The other authors have no conflicts of interest to report.
References
-
- Rose EA, Gelijns AC, Moskowitz AJ, et al.; Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure (REMATCH) Study Group: Long-term use of a left ventricular assist device for end-stage heart failure. N Engl J Med. 345: 1435–1443, 2001.
-
- Saeed D, Feldman D, Banayosy AE, et al.: The 2023 International Society for Heart and Lung Transplantation guidelines for mechanical circulatory support: A 10-year update. J Heart Lung Transplant. 42: e1–e222, 2023.
-
- Kormos RL, Cowger J, Pagani FD, et al.: The Society of Thoracic Surgeons Intermacs database annual report: Evolving indications, outcomes, and scientific partnerships. J Heart Lung Transplant. 38: 114–126, 2019.
-
- Apostoli A, Bianchi V, Bono N, et al.: Prothrombotic activity of cytokine-activated endothelial cells and shear-activated platelets in the setting of ventricular assist device support. J Heart Lung Transplant. 38: 658–667, 2019.
-