Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2024 Apr 11;16(4):e58047.
doi: 10.7759/cureus.58047. eCollection 2024 Apr.

The Validity and Reliability of a Smartphone Application for Measuring Wrist and Metacarpophalangeal Joint Motion

Affiliations

The Validity and Reliability of a Smartphone Application for Measuring Wrist and Metacarpophalangeal Joint Motion

Ömer Faruk Özçelep et al. Cureus. .

Abstract

Background Accurate measurement of the range of motion (ROM) is crucial for guiding upper extremity rehabilitation. Inaccurate measurements can mislead clinicians and harm patient compliance. This study aimed to evaluate the validity and reliability of a smartphone application (Angulus) for measuring wrist and metacarpophalangeal (MCP) joint ROM. Methodology This study included 64 volunteers with no prior wrist injuries. The wrist flexion/extension, radial/ulnar deviation, and MCP joint flexion/extension ROM were assessed by an experienced physiotherapist (Assessor 1) using the Angulus and a standard two-arm goniometer. The validity of Angulus was evaluated by correlating it with the goniometer measurements using the Pearson correlation coefficient. For the reliability analysis, an inexperienced biomedical engineer (Assessor 2) performed the same measurements using Angulus twice in different sessions, in addition to Assessor 1. The intra-rater and inter-rater reliability were tested using the intraclass correlation coefficient. Results The mean age of the participants was 29.5 ± 8.2 years, with 62% being female. The validity of the Angulus app measurements was indicated by the adequate to excellent correlation between the Angulus and goniometer measurements (ranging from 0.44 to 0.81). The intra-rater reliability of the Angulus app was excellent for Assessor 1 (ranging from 0.76 to 0.90) and adequate to excellent for Assessor 2 (ranging from 0.71 to 0.88). The inter-rater reliability of Angulus was excellent (ranging from 0.91 to 0.96). Conclusions Angulus is a valid and reliable method to measure the wrist and MCP joint ROM.

Keywords: metacarpophalangeal joint; mobile phone application; range of motion (rom); reliability and validity; wrist evaluation.

PubMed Disclaimer

Conflict of interest statement

The authors have declared that no competing interests exist.

Figures

Figure 1
Figure 1. Angulus measurements.
(A) Wrist flexion. (B) Wrist extension. (C) Ulnar deviation. (D) Radial deviation. (E) Metacarpophalangeal flexion. (F) Metacarpophalangeal extension.
Figure 2
Figure 2. Goniometric measurements.
(A) Wrist flexion. (B) Wrist extension. (C) Ulnar deviation. (D) Radial deviation. (E) Metacarpophalangeal flexion. (F) Metacarpophalangeal extension.

References

    1. Magee D. Orthopedic Physical Assessment, 6th ed. New York: Saunders; 2013. Orthopedic Physical Assessment.
    1. Reliability and validity of electro-goniometric range of motion measurements in patients with hand and wrist limitations. Bashardoust Tajali S, MacDermid JC, Grewal R, Young C. Open Orthop J. 2016;10:190–205. - PMC - PubMed
    1. Utility of the iPhone 4 gyroscope application in the measurement of wrist motion. Lendner N, Wells E, Lavi I, Kwok YY, Ho PC, Wollstein R. Hand (N Y) 2019;14:352–356. - PMC - PubMed
    1. Economic impact of hand and wrist injuries: health-care costs and productivity costs in a population-based study. de Putter CE, Selles RW, Polinder S, Panneman MJ, Hovius SE, van Beeck EF. J Bone Joint Surg Am. 2012;94:0. - PubMed
    1. Accuracy and reliability of three different techniques for manual goniometry for wrist motion: a cadaveric study. Carter TI, Pansy B, Wolff AL, Hillstrom HJ, Backus SI, Lenhoff M, Wolfe SW. J Hand Surg Am. 2009;34:1422–1428. - PubMed

LinkOut - more resources