Performance of Subcutaneous Continuous Glucose Monitoring in Adult Critically Ill Patients Receiving Vasopressor Therapy
- PMID: 38758211
- DOI: 10.1089/dia.2024.0035
Performance of Subcutaneous Continuous Glucose Monitoring in Adult Critically Ill Patients Receiving Vasopressor Therapy
Abstract
Background: Subcutaneous continuous glucose monitoring (CGM) may facilitate glucose control in the ICU. We aimed to assess the accuracy of CGM (Dexcom G6) against arterial blood glucose (ABG) in adult critically ill patients receiving intravenous insulin infusion and vasopressor therapy. We also aimed to assess feasibility and tolerability of CGM in this setting. Methods: We included ICU patients receiving mechanical ventilation, insulin, and vasopressor therapy. Numerical accuracy was assessed by the mean absolute relative difference (MARD), overall, across arterial glucose strata, over different noradrenaline equivalent infusion rates, and over time since CGM start. MARD <14% was considered acceptable. Clinical accuracy was assessed using Clarke Error Grid (CEG) analysis. Feasibility outcome included number and duration of interrupted sensor readings due to signal loss. Tolerability outcome included skin reactions related to sensor insertion or sensor adhesives. Results: We obtained 2946 paired samples from 40 patients (18 with type 2 diabetes) receiving a median (IQR) maximum noradrenaline equivalent infusion rate of 0.18 (0.08-0.33) µg/kg/min during CGM. Overall, MARD was 12.7% (95% CI 10.7-15.3), and 99.8% of CGM readings were within CEG zones A and B. MARD values ≥14% were observed when ABG was outside target range (6-10 mmol/L [108-180 mg/dL]) and with noradrenaline equivalent infusion rates above 0.10 µg/kg/min. Accuracy improved with time after CGM start, reaching MARD values <14% after 36 h. We observed four episodes of interrupted sensor readings due to signal loss, ranging from 5 to 20 min. We observed no skin reaction related to sensor insertion or sensor adhesives. Conclusions: In our ICU cohort of patients receiving vasopressor infusion, subcutaneous CGM demonstrated acceptable overall numerical and clinical accuracy. However, suboptimal accuracy may occur outside glucose ranges of 6-10 mmol/L (108-180 mg/dL), during higher dose vasopressor infusion, and during the first 36 h after CGM start.
Keywords: accuracy; continuous glucose monitoring; critical illness; diabetes.
Similar articles
-
Continuous Glucose Monitoring in Critically Ill Patients With COVID-19: Results of an Emergent Pilot Study.J Diabetes Sci Technol. 2020 Nov;14(6):1065-1073. doi: 10.1177/1932296820964264. Epub 2020 Oct 16. J Diabetes Sci Technol. 2020. PMID: 33063556 Free PMC article.
-
Glycemic control and blood gas sampling frequency during continuous glucose monitoring in the intensive care unit: A before-and-after study.Acta Anaesthesiol Scand. 2023 Jan;67(1):86-93. doi: 10.1111/aas.14159. Epub 2022 Oct 28. Acta Anaesthesiol Scand. 2023. PMID: 36263915 Free PMC article.
-
A Prospective Multicenter Evaluation of the Accuracy of a Novel Implanted Continuous Glucose Sensor: PRECISE II.Diabetes Technol Ther. 2018 Mar;20(3):197-206. doi: 10.1089/dia.2017.0142. Epub 2018 Jan 30. Diabetes Technol Ther. 2018. PMID: 29381090 Free PMC article.
-
Continuous Glucose Monitoring: A Review of Recent Studies Demonstrating Improved Glycemic Outcomes.Diabetes Technol Ther. 2017 Jun;19(S3):S25-S37. doi: 10.1089/dia.2017.0035. Diabetes Technol Ther. 2017. PMID: 28585879 Free PMC article. Review.
-
Accuracy of Freestyle Libre continuous glucose monitoring system in critically ill patients after cardiac surgery.J Cardiothorac Surg. 2025 Jan 20;20(1):75. doi: 10.1186/s13019-024-03229-1. J Cardiothorac Surg. 2025. PMID: 39833920 Free PMC article. Review.
Cited by
-
Accuracy of Glucose Trends by Subcutaneous Continuous Monitoring vs Intermittent Arterial Measurements in Critically Ill Patients.J Diabetes Sci Technol. 2025 Jul 24:19322968251358830. doi: 10.1177/19322968251358830. Online ahead of print. J Diabetes Sci Technol. 2025. PMID: 40704488 Free PMC article.
-
Accuracy of continuous glucose monitoring systems in intensive care unit patients: a scoping review.Intensive Care Med. 2024 Dec;50(12):2005-2018. doi: 10.1007/s00134-024-07663-6. Epub 2024 Oct 17. Intensive Care Med. 2024. PMID: 39417874
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Research Materials
Miscellaneous