Segmental coronary artery disease: detection by rotating slant-hole collimator tomography and planar thallium 201 myocardial scintigraphy
- PMID: 3875879
- DOI: 10.1148/radiology.157.1.3875879
Segmental coronary artery disease: detection by rotating slant-hole collimator tomography and planar thallium 201 myocardial scintigraphy
Abstract
Normal quantitative circumferential profile limits were established for a 30 degrees bilateral rotating slant-hole (RSH) collimator tomographic system. This system's value in detecting segmental coronary artery disease was assessed in a study evaluating 196 patients by thallium 201 myocardial scintigraphy and coronary arteriography. Profile curves were calculated from images of 20 healthy patients and used to identify significant coronary artery disease (greater than or equal to 70% diameter narrowing) in the left anterior descending (LAD), the right, and the left circumflex (LCx) coronary arteries. In a group of 86 patients, an abnormality on the apical or middle plane optimally identified segmental coronary artery disease. When such abnormalities were prospectively evaluated in a test group of 110 patients, the sensitivity and specificity were 79% and 93% for LAD, 90% and 90% for right, and 83% and 83% for LCx coronary artery disease. Compared with qualitative interpretation of the planar and tomographic images, quantitative tomography significantly improved the sensitivity of T1-201 imaging in detecting LAD, right, and LCx coronary artery disease (P less than .001) in patients with or without previous myocardial infarction.
Similar articles
-
Thallium-201 scintigraphy for ischaemic heart disease and infarct detection: comparison of rotating slant-hole tomography and planar imaging.Br J Radiol. 1985 Jul;58(691):625-34. doi: 10.1259/0007-1285-58-691-625. Br J Radiol. 1985. PMID: 3874673
-
Segmental analysis of stress thallium myocardial emission tomography for localization of coronary artery disease.Eur J Nucl Med. 1984;9(3):99-105. doi: 10.1007/BF00253509. Eur J Nucl Med. 1984. PMID: 6609076
-
[Quantitative analysis of exercise 201Tl myocardial emission CT in patients with coronary artery disease].J Cardiogr. 1984 Dec;14(4):635-43. J Cardiogr. 1984. PMID: 6336172 Japanese.
-
Adenosine thallium 201 myocardial perfusion scintigraphy.Am Heart J. 1991 Jul;122(1 Pt 1):269-78; discussion 302-6. doi: 10.1016/0002-8703(91)90800-w. Am Heart J. 1991. PMID: 2063756 Review.
-
Thallium imaging with single photon emission computed tomography.Am Heart J. 1987 Oct;114(4 Pt 1):852-65. doi: 10.1016/0002-8703(87)90796-4. Am Heart J. 1987. PMID: 3310567 Review.
Cited by
-
Myocardial scintigraphy--25 years after start.Eur J Nucl Med. 1988;13(12):619-36. doi: 10.1007/BF00256390. Eur J Nucl Med. 1988. PMID: 3282885 Review.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources