Analysis of some errors in the measurement of oxygen extraction and oxygen consumption by the equilibrium inhalation method
- PMID: 3877066
- DOI: 10.1038/jcbfm.1985.88
Analysis of some errors in the measurement of oxygen extraction and oxygen consumption by the equilibrium inhalation method
Abstract
Some sources of error in the equilibrium inhalation method for the measurement of oxygen extraction fraction and CMRO2 by positron emission computed tomography scanning have been evaluated by computer simulation. Emphasis has been placed on errors that have not been thoroughly studied in past work. These include effects of random statistical errors, systematic errors in arterial blood radioactivity concentrations, and errors due to perturbations of the equilibrium state, to tissue inhomogeneity, and to subject motion.
Similar articles
-
Correction for the presence of intravascular oxygen-15 in the steady-state technique for measuring regional oxygen extraction ratio in the brain: 1. Description of the method.J Cereb Blood Flow Metab. 1983 Dec;3(4):416-24. doi: 10.1038/jcbfm.1983.67. J Cereb Blood Flow Metab. 1983. PMID: 6630313
-
Cerebral blood volume measured with inhaled C15O and positron emission tomography.J Cereb Blood Flow Metab. 1987 Aug;7(4):421-6. doi: 10.1038/jcbfm.1987.85. J Cereb Blood Flow Metab. 1987. PMID: 3497162
-
Separation of input function for rapid measurement of quantitative CMRO2 and CBF in a single PET scan with a dual tracer administration method.Phys Med Biol. 2007 Apr 7;52(7):1893-908. doi: 10.1088/0031-9155/52/7/009. Epub 2007 Mar 12. Phys Med Biol. 2007. PMID: 17374918
-
[The use of radionuclides, specifically positron-emission tomography, in the determination of the blood circulation and metabolism of the brain. Application in experimental cerebral embolism].Verh K Acad Geneeskd Belg. 1989;51(4):315-76. Verh K Acad Geneeskd Belg. 1989. PMID: 2690540 Review. Dutch.
-
Cerebral perfusion and oxygen uptake studies in patients with intracranial tumors.Semin Neurol. 1989 Dec;9(4):377-87. doi: 10.1055/s-2008-1041348. Semin Neurol. 1989. PMID: 2701782 Review. No abstract available.
Cited by
-
Positron emission tomography and in vivo measurements of tumour perfusion and oxygen utilisation.Cancer Metastasis Rev. 1987;6(4):521-39. doi: 10.1007/BF00047466. Cancer Metastasis Rev. 1987. PMID: 3327631 Review.
-
Quantification of brain oxygen extraction and metabolism with [15O]-gas PET: A technical review in the era of PET/MRI.Neuroimage. 2020 Oct 15;220:117136. doi: 10.1016/j.neuroimage.2020.117136. Epub 2020 Jul 4. Neuroimage. 2020. PMID: 32634594 Free PMC article. Review.
-
Measurement accuracy and practicality of 15O-gas PET using a high-sensitivity whole-body PET/CT scanner.Ann Nucl Med. 2025 Jun 25. doi: 10.1007/s12149-025-02073-0. Online ahead of print. Ann Nucl Med. 2025. PMID: 40562958
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Miscellaneous