Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2024 May 14;10(5):119.
doi: 10.3390/jimaging10050119.

The Accuracy of Three-Dimensional Soft Tissue Simulation in Orthognathic Surgery-A Systematic Review

Affiliations
Review

The Accuracy of Three-Dimensional Soft Tissue Simulation in Orthognathic Surgery-A Systematic Review

Anna Olejnik et al. J Imaging. .

Abstract

Three-dimensional soft tissue simulation has become a popular tool in the process of virtual orthognathic surgery planning and patient-surgeon communication. To apply 3D soft tissue simulation software in routine clinical practice, both qualitative and quantitative validation of its accuracy are required. The objective of this study was to systematically review the literature on the accuracy of 3D soft tissue simulation in orthognathic surgery. The Web of Science, PubMed, Cochrane, and Embase databases were consulted for the literature search. The systematic review (SR) was conducted according to the PRISMA statement, and 40 articles fulfilled the inclusion and exclusion criteria. The Quadas-2 tool was used for the risk of bias assessment for selected studies. A mean error varying from 0.27 mm to 2.9 mm for 3D soft tissue simulations for the whole face was reported. In the studies evaluating 3D soft tissue simulation accuracy after a Le Fort I osteotomy only, the upper lip and paranasal regions were reported to have the largest error, while after an isolated bilateral sagittal split osteotomy, the largest error was reported for the lower lip and chin regions. In the studies evaluating simulation after bimaxillary osteotomy with or without genioplasty, the highest inaccuracy was reported at the level of the lips, predominantly the lower lip, chin, and, sometimes, the paranasal regions. Due to the variability in the study designs and analysis methods, a direct comparison was not possible. Therefore, based on the results of this SR, guidelines to systematize the workflow for evaluating the accuracy of 3D soft tissue simulations in orthognathic surgery in future studies are proposed.

Keywords: data accuracy; orthognathic surgery; orthognathic surgical procedures; patient simulation; three-dimensional image.

PubMed Disclaimer

Conflict of interest statement

The authors declare that there are no competing interests.

Figures

Figure 1
Figure 1
PRISMA 2020 flow diagram.

References

    1. Swennen G.R.J., Schutyser F., Barth E.-L., De Groeve P., De Mey A. A New Method of 3-D Cephalometry Part I. J. Craniofacial Surg. 2006;17:314–325. doi: 10.1097/00001665-200603000-00019. - DOI - PubMed
    1. Swennen G.R.J., Schutyser F., Hausamen J.-E. Three-Dimensional Cephalometry. Springer; Berlin/Heidelberg, Germany: 2006. p. 291. Chapter 8.
    1. Mollemans W., Schutyser F., Nadjmi N., Maes F., Suetens P. Predicting soft tissue deformations for a maxillofacial surgery planning system: From computational strategies to a complete clinical validation. Med. Image Anal. 2007;11:282–301. doi: 10.1016/j.media.2007.02.003. - DOI - PubMed
    1. Arnett G.W., Gunson M.J. Facial planning for orthodontists and Oral surgeons. Am. J. Orthod. Dentofac. Orthop. 2004;126:290–295. doi: 10.1016/j.ajodo.2004.06.006. - DOI - PubMed
    1. Kim D., Kuang T., Rodrigues Y.L., Gateno J., Shen S.G.F., Wang X., Deng H., Yuan P., Alfi D.M., Liebschner M.A.K., et al. A New Approach of Predicting Facial Changes Following Orthognathic Surgery Using Realistic Lip Sliding Effect. Springer; Berlin/Heidelberg, Germany: 2019. pp. 336–344. - PMC - PubMed