Time In Tight Range in children and adolescents with type 1 diabetes: A cross-sectional observational single centre study evaluating efficacy of new advanced technologies
- PMID: 38824455
- DOI: 10.1002/dmrr.3826
Time In Tight Range in children and adolescents with type 1 diabetes: A cross-sectional observational single centre study evaluating efficacy of new advanced technologies
Abstract
Introduction: Early and tight glycaemic control is crucial to prevent long-term complications of Type 1 Diabetes (T1D). The aim of our study was to compare glucose metrics, including Time In Tight Range (TITR), in a real-world setting.
Methods: We performed a single-centre cross-sectional study in 534 children and adolescents with T1D. Participants were divided into four groups (multiple daily injections + real-time Continuous glucose monitoring (CGM), multiple daily injections + intermittently scanned CGM, sensor augmented pump (SAP), and Advanced Hybrid Closed-Loop (AHCL). Demographical and clinical data were collected and analysed.
Results: The group with AHCL showed significantly higher Time In Range (TIR) (71.31% ± 10.88) than SAP (57.82% ± 14.98; p < 0.001), MDI + rtCGM (54.56% ± 17.04; p < 0.001) and MDI + isCGM (52.17% ± 19.36; p < 0.001) groups with a lower Time Above Range (p < 0.001). The group with AHCL also showed lower Time Below Range than MDI + isCGM and SAP groups (p < 0.01). The overall TITR was 37% ± 14 with 19% of participants who reached a TITR ≥50% with a mean TIR of 81%. AHCL had significantly higher TITR (45.46% ± 11.77) than SAP (36.25% ± 13.53; p < 0.001), MDI + rtCGM (34.03% ± 13.89; p < 0.001) and MDI + isCGM (33.37% ± 15.84; p < 0.001) groups with a lower Coefficient of Variation (p < 0.001).
Conclusions: Our study indicates that AHCL ensures a better glycaemic control with an improvement in both TIR and TITR, along with a reduction in CV. Implementation of automated insulin delivery systems should be considered in the treatment of children and adolescents with T1D.
Keywords: children; technologies; type 1 diabetes.
© 2024 The Author(s). Diabetes/Metabolism Research and Reviews published by John Wiley & Sons Ltd.
References
REFERENCES
-
- Foster NC, Beck RW, Miller KM, et al. T1 Diabetes Exchange. State of type 1 diabetes management and outcomes from the T1D Exchange in 2016‐2018. Diabetes Technol Ther. 2019;21(2):66‐72. https://doi.org/10.1089/dia.2018.0384
-
- Nathan DM, Bayless M, Cleary P, et al. DCCT/EDIC Research Group. Diabetes control and complications trial/epidemiology of diabetes interventions and complications study at 30 years: advances and contributions. Diabetes. 2013;62(12):3976‐3986. https://doi.org/10.2337/db13‐1093
-
- Gerstein HC, Ambrosius WT, Danis R, et al. ACCORD Study Group. Diabetic retinopathy, its progression, and incident cardiovascular events in the ACCORD trial. Diabetes Care. 2013;36(5):1266‐1271. https://doi.org/10.2337/dc12‐1311
-
- Lachin JM, Bebu I, DCCT/EDIC Research Group. The beneficial effects of earlier versus later implementation of intensive therapy in type 1 diabetes. Diabetes Care. 2021;44(10):2225‐2230. https://doi.org/10.2337/dc21‐1331
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous