Evaluation of an enzyme-linked immunosorbent assay for treponemal antibody
- PMID: 3884657
- PMCID: PMC271673
- DOI: 10.1128/jcm.21.3.399-402.1985
Evaluation of an enzyme-linked immunosorbent assay for treponemal antibody
Abstract
A new enzyme-linked immunosorbent assay with Treponema pallidum antigen bound to ferrous metal beads (Syphilis Bio-EnzaBead; Litton Bionetics Laboratory Products) was compared with the standard fluorescent treponemal antibody-absorption test for syphilis. Bio-EnzaBead and fluorescent treponemal antibody-absorption tests were done on 218 specimens from documented cases of syphilis, on 315 sera from individuals with diseases other than syphilis, and on sera submitted to a public health laboratory for premarital (304 specimens) or diagnostic (501 specimens) tests for syphilis. Agreement between the Bio-EnzaBead and reference tests ranged from 93.0% for sera for the diagnostic test to 99.5% for sera from patients with syphilis. The overall agreement among the 1,338 sera tested was 96.3%. The reproducibility of the Bio-EnzaBead test with 60 coded sera of graded reactivity was 97%. The test is easy to perform, the indicator results are clear and unequivocal, and the findings are comparable to those of the fluorescent treponemal antibody-absorption test.
Similar articles
-
Evaluation of the syphilis Bio-EnzaBead assay for detection of treponemal antibody.J Clin Microbiol. 1987 May;25(5):808-11. doi: 10.1128/jcm.25.5.808-811.1987. J Clin Microbiol. 1987. PMID: 3294884 Free PMC article.
-
Four-step enzyme-linked immunosorbent assay for detection of Treponema pallidum antibody.J Clin Microbiol. 1985 Mar;21(3):387-9. doi: 10.1128/jcm.21.3.387-389.1985. J Clin Microbiol. 1985. PMID: 3884654 Free PMC article.
-
Specificity, sensitivity, and reproducibility among the fluorescent treponemal antibody-absorption test, the microhemagglutination assay for Treponema pallidum antibodies, and the hemagglutination treponemal test for syphilis.J Clin Microbiol. 1981 Oct;14(4):441-5. doi: 10.1128/jcm.14.4.441-445.1981. J Clin Microbiol. 1981. PMID: 7026610 Free PMC article.
-
Laboratory diagnosis and interpretation of tests for syphilis.Clin Microbiol Rev. 1995 Jan;8(1):1-21. doi: 10.1128/CMR.8.1.1. Clin Microbiol Rev. 1995. PMID: 7704889 Free PMC article. Review.
-
The fluorescent treponemal antibody-absorption (FTA-ABS) test for syphilis.CRC Crit Rev Clin Lab Sci. 1975 Jan;5(3):315-30. doi: 10.3109/10408367509107046. CRC Crit Rev Clin Lab Sci. 1975. PMID: 1092525 Review.
Cited by
-
Enzyme linked immunosorbent assays with Treponema pallidum or axial filament of T phagedenis biotype Reiter as antigen: evaluation as screening tests for syphilis.Genitourin Med. 1986 Dec;62(6):367-72. doi: 10.1136/sti.62.6.367. Genitourin Med. 1986. PMID: 3546079 Free PMC article.
-
Enzyme immunoassay for anti-treponemal IgG: screening or confirmatory test?J Clin Pathol. 1992 Jan;45(1):37-41. doi: 10.1136/jcp.45.1.37. J Clin Pathol. 1992. PMID: 1740512 Free PMC article.
-
Evaluation of the Bio-EnzaBead test for syphilis.J Clin Microbiol. 1987 Apr;25(4):619-23. doi: 10.1128/jcm.25.4.619-623.1987. J Clin Microbiol. 1987. PMID: 3553231 Free PMC article.
-
Evaluation of the Captia enzyme immunoassays for detection of immunoglobulins G and M to Treponema pallidum in syphilis.J Clin Microbiol. 1990 Aug;28(8):1704-7. doi: 10.1128/jcm.28.8.1704-1707.1990. J Clin Microbiol. 1990. PMID: 2203809 Free PMC article.
-
Enzyme-linked immunofiltration assay for rapid serodiagnosis of syphilis.Eur J Clin Microbiol. 1987 Jun;6(3):281-5. doi: 10.1007/BF02017613. Eur J Clin Microbiol. 1987. PMID: 3305006
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources