Left ventricular border recognition using a dynamic search algorithm
- PMID: 3885315
- DOI: 10.1148/radiology.155.2.3885315
Left ventricular border recognition using a dynamic search algorithm
Abstract
Initial results obtained with a simple, fully automated algorithm for detection of left ventricular boundaries are presented. The strength of this approach is the use of dynamic programming search techniques, which allow determination of local border points to be influenced by the entire global border location. The relative contributions of mask mode subtraction and the dynamic search technique are evaluated with respect to accurate border definition. These computer-determined ventricular borders are compared with hand-traced borders on subtracted and unsubtracted images. The modular dynamic search algorithm is shown to perform better than previously described algorithms, which generally require operator interaction. It is also shown that for both manual and automated techniques, ventricular borders derived from subtracted images may be significantly different from borders derived from nonsubtracted images.
Similar articles
-
[Digital subtraction angiocardiography: accuracy of left ventricular volume determination using intravenous injection of contrast medium].Z Kardiol. 1983 May;72(5):262-7. Z Kardiol. 1983. PMID: 6349159 German.
-
Radionuclide angiocardiography, a noninvasive method for evaluating left ventricular ejection fraction and regional wall motion; comparison with contrast left ventricular angiography.Can Med Assoc J. 1978 Oct 21;119(8):877-83. Can Med Assoc J. 1978. PMID: 757954 Free PMC article.
-
[Comparison of densitometric and morphometric measurements of global and regional functions using a fully digital subtraction unit].Rofo. 1985 Apr;142(4):411-8. doi: 10.1055/s-2008-1052677. Rofo. 1985. PMID: 2986218 German.
-
Myocardial border detection by branch-and-bound dynamic programming in magnetic resonance images.Comput Methods Programs Biomed. 2005 Jul;79(1):19-29. doi: 10.1016/j.cmpb.2004.10.010. Comput Methods Programs Biomed. 2005. PMID: 15896871
-
Left ventricular ejection fraction--a review of several radionuclide angiographic approaches using the scintillation camera.Prog Cardiovasc Dis. 1978 Jan-Feb;20(4):267-84. doi: 10.1016/0033-0620(78)90014-2. Prog Cardiovasc Dis. 1978. PMID: 341222 Review. No abstract available.
Cited by
-
Validation of a new automatic system for biplane quantitative coronary arteriography.Int J Card Imaging. 1990;5(2-3):93-103. doi: 10.1007/BF01833978. Int J Card Imaging. 1990. PMID: 2230301
-
Comparative evaluation of active contour model extensions for automated cardiac MR image segmentation by regional error assessment.MAGMA. 2007 Apr;20(2):69-82. doi: 10.1007/s10334-007-0069-z. Epub 2007 Mar 6. MAGMA. 2007. PMID: 17340125
-
Lossy JPEG compression in quantitative angiography: the role of X-ray quantum noise.J Digit Imaging. 2011 Jun;24(3):516-27. doi: 10.1007/s10278-010-9275-8. J Digit Imaging. 2011. PMID: 20169463 Free PMC article.
-
Optimal surface segmentation in volumetric images--a graph-theoretic approach.IEEE Trans Pattern Anal Mach Intell. 2006 Jan;28(1):119-34. doi: 10.1109/TPAMI.2006.19. IEEE Trans Pattern Anal Mach Intell. 2006. PMID: 16402624 Free PMC article.
-
Region detection by minimizing intraclass variance with geometric constraints, global optimality, and efficient approximation.IEEE Trans Med Imaging. 2011 Mar;30(3):814-27. doi: 10.1109/TMI.2010.2095870. Epub 2010 Nov 29. IEEE Trans Med Imaging. 2011. PMID: 21118766 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources