EANM perspectives for CZT SPECT in brain applications
- PMID: 38858281
- DOI: 10.1007/s00259-024-06788-6
EANM perspectives for CZT SPECT in brain applications
Erratum in
-
Correction to: EANM perspectives for CZT SPECT in brain applications.Eur J Nucl Med Mol Imaging. 2024 Oct;51(12):3807. doi: 10.1007/s00259-024-06842-3. Eur J Nucl Med Mol Imaging. 2024. PMID: 39017919 No abstract available.
Similar articles
-
Comparison of conventional and cadmium-zinc-telluride single-photon emission computed tomography for analysis of thallium-201 myocardial perfusion imaging: an exploratory study in normal databases for different ethnicities.Int J Cardiovasc Imaging. 2017 Dec;33(12):2057-2066. doi: 10.1007/s10554-017-1205-0. Epub 2017 Jun 29. Int J Cardiovasc Imaging. 2017. PMID: 28664481
-
EANM position paper on challenges and opportunities of full-ring 360° CZT bone imaging: it's time to let go of planar whole-body bone imaging.Eur J Nucl Med Mol Imaging. 2025 Feb;52(3):1200-1209. doi: 10.1007/s00259-024-06906-4. Epub 2024 Sep 11. Eur J Nucl Med Mol Imaging. 2025. PMID: 39259227 Free PMC article. Review.
-
Head-to-head comparison of diagnostic accuracy of stress-only myocardial perfusion imaging with conventional and cadmium-zinc telluride single-photon emission computed tomography in women with suspected coronary artery disease.J Nucl Cardiol. 2021 Jun;28(3):888-897. doi: 10.1007/s12350-019-01789-7. Epub 2019 Jun 20. J Nucl Cardiol. 2021. PMID: 31222530
-
Evaluation of a variable-aperture full-ring SPECT system using large-area pixelated CZT modules: A simulation study for brain SPECT applications.Med Phys. 2021 May;48(5):2301-2314. doi: 10.1002/mp.14836. Epub 2021 Mar 30. Med Phys. 2021. PMID: 33704793 Free PMC article.
-
Performance of cardiac cadmium-zinc-telluride gamma camera imaging in coronary artery disease: a review from the cardiovascular committee of the European Association of Nuclear Medicine (EANM).Eur J Nucl Med Mol Imaging. 2016 Dec;43(13):2423-2432. doi: 10.1007/s00259-016-3467-5. Epub 2016 Aug 19. Eur J Nucl Med Mol Imaging. 2016. PMID: 27542010 Review.
References
-
- Agostini D, Marie P-Y, Ben-Haim S, Rouzet F, Songy B, Giordano A, et al. Performance of cardiac cadmium-zinc-telluride gamma camera imaging in coronary artery disease: a review from the cardiovascular committee of the European Association of Nuclear Medicine (EANM). Eur J Nucl Med Mol Imaging. 2016;43:2423–32. - PubMed - DOI
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources