Comparative Study
. 2024 Jun 11;58(1):129-137.
doi: 10.2478/enr-2024-0014. Print 2024 Jan 1.

Comparison the accuracy of thyroid sono-elastography vs. ultrasound-guided fine needle aspiration cytology with thyroid malignancy diagnosis histopathology

Affiliations
Free article
Comparative Study

Comparison the accuracy of thyroid sono-elastography vs. ultrasound-guided fine needle aspiration cytology with thyroid malignancy diagnosis histopathology

Sarah Abd Elmageed Mahmoud et al. Endocr Regul. .
Free article

Abstract

Objective. The intend of the present study was to assess the diagnostic performance of strain elastography in investigating the thyroid nodule malignancy taking the surgical biopsy as a gold standard reference test. Methods. The study included 120 patients with 123 thyroid nodules, of which 67 had total thyroidectomy. The American College of Radiology Thyroid Imaging Reporting and Data Systems (ACR-TIRADS) were evaluated for all nodules. All suspicious nodules were referred for a fine needle aspiration cytology (FNAC) if they fulfilled the required size. Strain elastography was performed for each suspicious nodule. Ultrasound-guided FNAC was performed for all suspicious nodules. Total thyroidectomy was performed in those whom the suspicious nodules were proven by FNAC. Results. Strain ratio had a sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of 84%, 81%, 95%, 85%, and 84%, respectively, with a cut point 1.96. Elasticity score had a sensitivity, specificity, PPV, NPV, and diagnostic accuracy of 100%, 80%, 95%, 85% and 87%, respectively, with a cut point 0.96. The elasticity score had a statistically significantly odds ratio for detecting the benignity 3.9 C. I (1.6-9.3). Conclusion. Strain elastography has a high diagnostic performance in detecting the malignant as well as benign nodules, thus it can limit the rate of unneeded FNAC or surgery especially among B3 and B4 groups with indeterminate cytology.

Keywords: elastography; malignancy; nodules; thyroid.

PubMed Disclaimer

Similar articles

References

    1. Aksoy SO, Sevinc AI, Durak MG. Hyperthyroidism with thyroid cancer: more common than expected? Ann Ital Chir 91, 16–22, 2020.
    1. Alexander EK, Marqusee E, Orcutt J, Benson CB, Frates MC, Doubilet PM, Cibas ES, Atri A. Thyroid nodule shape and prediction of malignancy. Thyroid 14, 953–958, 2004.
    1. Alhassan R, Al Busaidi N, Al Rawahi AH, Al Musalhi H, Al Muqbali A, Shanmugam P, Ramadhan FA. Features and diagnostic accuracy of fine needle aspiration cytology of thyroid nodules: retrospective study from Oman. Ann Saudi Med 42, 246–251, 2022.
    1. Bongiovanni M, Bellevicine C, Troncone G, Sykiotis GP. Approach to cytological indeterminate thyroid nodules. Gland Surgery 8, S98–S104, 2019.
    1. Brito JP, Gionfriddo MR, Al Nofal A, Boehmer KR, Leppin AL, Reading C, Callstrom M, Elraiyah TA, Prokop LJ, Stan MN, Murad MH, Morris JC, Montori VM. The accuracy of thyroid nodule ultrasound to predict thyroid cancer: systematic review and meta-analysis. J Clin Endocrinol Metab 99, 1253–1263, 2014.

Publication types

MeSH terms

LinkOut - more resources