Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2024 Jun 7;70(suppl 1):e2024S131.
doi: 10.1590/1806-9282.2024S131. eCollection 2024.

Biopsy of bone tumors: a literature review

Affiliations
Review

Biopsy of bone tumors: a literature review

Alex Guedes et al. Rev Assoc Med Bras (1992). .
No abstract available

PubMed Disclaimer

Conflict of interest statement

Conflicts of interest: the authors declare there is no conflicts of interest.

Figures

Figure 1
Figure 1. (A) Adamantinoma of the tibia: the piece was resected en bloc with the scar and biopsy path. (B) Osteosarcoma of the distal femur; intraoperative aspect of the procedure of wide tumor resection, biological reconstruction, and fixation - three-dimensional resection of the biopsy pathway, resected together with the specimen in sequence.
Figure 2
Figure 2. (A-D). Core needle biopsies. (A) A 40-year-old female patient with suspected enchondroma/chondrosarcoma in the proximal segment of the right humerus. A radioscopy-guided biopsy of the affected segment was performed with trephine. Diagnosis of grade 1 chondrosarcoma was confirmed. (B) A 52-year-old male patient with suspected metastatic lesion of undetermined origin in the right iliac. A radioscopy-guided biopsy with trephine was performed. Diagnosis of mesenchymal chondrosarcoma was made. (C) A 30-year-old female patient with a bone lesion in the left iliac. A radioscopy guided biopsy with trephine was performed. A diagnosis of simple bone cyst was made. (D) Jamshidi needle for bone biopsy mounted next to the extraction probe ("pusher"); chuck and trocar hinge at the T-handle; The trocar has a tapered stylet tip and the chuck features a "triple-crown" type cannula tip - these features provide a sharp and effective cutting tip for improved cortical penetration and medullary advancement that requires 25% less physical force. Appearance of the collection of four bone tumor samples.

Similar articles

Cited by

References

    1. Guedes A, Oliveira MBDR, Melo AS, Carmo CCMD. Update in imaging evaluation of bone and soft tissue sarcomas. Rev Bras Ortop (Sao Paulo) 2021;58(2):179–190. doi: 10.1055/s-0041-1736569. - DOI - PMC - PubMed
    1. Guedes A, Oliveira MBDR, Costa FM, Melo AS. Updating on bone and soft tissue sarcomas staging. Rev Bras Ortop (Sao Paulo) 2021;56(4):411–418. doi: 10.1055/s-0040-1710331. - DOI - PMC - PubMed
    1. Enneking WF, Spanier SS, Goodman MA. A system for the surgical staging of musculoskeletal sarcoma. Clin Orthop Relat Res. 1980;(153):106–120. - PubMed
    1. Errani C, Traina F, Perna F, Calamelli C, Faldini C. Current concepts in the biopsy of musculoskeletal tumors. ScientificWorldJournal. 2013;2013:538152–538152. doi: 10.1155/2013/538152. - DOI - PMC - PubMed
    1. Garcia JG, Marques DS, Viola DCM, Petrilli MT, Alves MTS, Jesus-Garcia R., Filho Biopsy path contamination in primary bone sarcomas. Rev Bras Ortop (Sao Paulo) 2019;54(1):33–36. doi: 10.1016/j.rbo.2017.09.006. - DOI - PMC - PubMed