Description of new sign of integral (∫) for rotational deformity of distal femur
- PMID: 38879841
- DOI: 10.1007/s00590-024-04011-8
Description of new sign of integral (∫) for rotational deformity of distal femur
Abstract
Purpose: Femur shaft fractures commonly occur due to high velocity trauma and most of them are fixed with nailing. Malrotation is common after fixation. A rotational malalignment more than 30° is a deformity which requires correction. Various techniques described for rotational deformities are: the 'cable techniques' for the determination of varus-valgus malalignment; the 'hyperextension test', 'radiographic recurvatum sign', 'tibial plateau sign', and 'meterstick technique' for length analysis; and the 'hip rotation test', 'lesser trochanter shape sign', 'cortical step sign', and 'diameter difference sign' for rotational analysis. We describe integration sign at the medial or lateral aspect of notch of femur in fixed internal or external rotation due to condensation of trabeculae.
Methods: This is a prospective observational study. Informed consent was taken, and this study was approved by institutional review board. C arm imaging study of 50 knees was done at our institution in which rotational profile of distal femur was analyzed In 3 different views -AP , Internal and external rotation views. The rotation views were taken sequentially and each observer was asked to identify the sign at its appearance and at rotation when it was best seen. All the observers were asked to draw the sign on linear line diagram of distal femur. The data was analysed statistically.
Results: Sign of integral (∫) for rotational deformity was seen at Mean external rotation of 22±1.71 with a range of 19 degree to 25 degree and Mean internal rotation of 15.78±1.21 with a range of 14 degree to 18 degree.
Conclusion: The integration sign can be used as intraoperative C arm sign to understand the rotational deformity of distal fragment of femur. This helps the surgeon to understand the alignment and revise if needed intraoperatively. If combined with position of lesser trochanter, this will give alignment for both proximal as well as distal fragment of femur.
Keywords: Condensation femoral notch; Femur malrotation; Sign of integration.
© 2024. The Author(s), under exclusive licence to Springer-Verlag France SAS, part of Springer Nature.
References
-
- Weiss RJ, Montgomery SM, Al Dabbagh Z, Jansson KA (2009) National data of 6409 Swedish inpatients with femoral shaft fractures: stable incidence between 1998 and 2004. Injury 40(3):304–308. https://doi.org/10.1016/j.injury.2008.07.017 - DOI - PubMed
-
- Enninghorst N, McDougall D, Evans JA, Sisak K, Balogh ZJ (2013) Population-based epidemiology of femur shaft fractures. J Trauma Acute Care Surg 74(6):1516–1520. https://doi.org/10.1097/TA.0b013e31828c3dc9 - DOI - PubMed
-
- Lindsey JD, Krieg JC (2011) Femoral malrotation following intramedullary nail fixation. J Am Acad Orthop Surg 19(1):17–26. https://doi.org/10.5435/00124635-201101000-00003 - DOI - PubMed
-
- Jaarsma RL, Pakvis DF, Verdonschot N, Biert J, van Kampen A (2004) Rotational malalignment after intramedullary nailing of femoral fractures. J Orthop Trauma 18(7):403–409. https://doi.org/10.1097/00005131-200408000-00002 - DOI - PubMed
-
- Tornetta P 3rd, Ritz G, Kantor A (1995) Femoral torsion after interlocked nailing of unstable femoral fractures. J Trauma 38(2):213–219. https://doi.org/10.1097/00005373-199502000-00011 - DOI - PubMed
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical