Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Case Reports
. 2024 Aug;104(2):419-421.
doi: 10.1002/ccd.31121. Epub 2024 Jun 16.

Simplified balloon-BASILICA: A different perspective

Affiliations
Case Reports

Simplified balloon-BASILICA: A different perspective

Nicolò Azzola Guicciardi et al. Catheter Cardiovasc Interv. 2024 Aug.

Abstract

Nowadays, the long-life management of patients with aortic stenosis has emerged as one of the most debated issues. Transcatheter aortic valve replacement is more frequently performed in younger patients with lower surgical risk, and also the number of valve-in-valve (ViV) procedures has increased in the last few years. However, coronary obstruction is the most dreadful complication related to this procedure. To prevent coronary obstruction in the context of transcatheter aortic ViV implantation, the BASILICA (bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction) technique was developed. Although effective, BASILICA is complex and time-consuming. Hence, simpler, reproducible, and faster strategies are desirable. Here we present a promising simplified BASILICA technique employing an Armada Balloon to perform the leaflet laceration.

Keywords: AVDP—aortic valve disease; AVD—aortic valve disease; PVT—percutaneous valve therapy; TVI—transcatheter valve implantation; percutaneous intervention.

PubMed Disclaimer

References

REFERENCES

    1. Ribeiro HB, Rodés‐Cabau J, Blanke P, et al. Incidence, predictors, and clinical outcomes of coronary obstruction following transcatheter aortic valve replacement for degenerative bioprosthetic surgical valves: insights from the VIVID registry. Eur Heart J. 2018;39(8):687‐695.
    1. Blanke P, Soon J, Dvir D, et al. Computed tomography assessment for transcatheter aortic valve in valve implantation: the Vancouver approach to predict anatomical risk for coronary obstruction and other considerations. J Cardiovasc Comput Tomogr. 2016;10(6):491‐499.
    1. Khan JM, Dvir D, Greenbaum AB, et al. Transcatheter laceration of aortic leaflets to prevent coronary obstruction during transcatheter aortic valve replacement. JACC Cardiovasc Intev. 2018;11(7):677‐689.
    1. Greenbaum AB, Kamioka N, Vavalle JP, et al. Balloon‐assisted BASILICA to facilitate redo TAVR. JACC Cardiovasc Interv. 2021;14(5):578‐580.
    1. Helmy T, Hui DS, Smart S, Lim MJ, Lee R. Balloon assisted translocation of the mitral anterior leaflet to prevent left ventricular outflow obstruction (BATMAN): a novel technique for patients undergoing transcatheter mitral valve replacement. Catheter Cardiovasc Interv. 2020;95(4):840‐848.