Accuracy of an autonomous dental implant robotic system in partial edentulism: A pilot clinical study

Affiliations

Accuracy of an autonomous dental implant robotic system in partial edentulism: A pilot clinical study

MiaoZhen Wang et al. Clin Oral Investig. .

Abstract

Objectives: Robots are increasingly being used for surgical procedures in various specialties. However, information about the accuracy of robot-assisted dental implant surgery is lacking. This pilot clinical study aimed to investigate the accuracy of an autonomous dental implant robotic (ADIR) system in partially edentulous cases.

Material and methods: The ADIR system was used to place a total of 20 implants in 13 participants. Implant deviation from the planned positions was assessed to determine accuracy. The entry, apex, and angular deviations were described as means ± standard deviation. A two-sample t test was used to compare implant deviation between the flap and flapless groups and between maxillary and mandibular implants (α = .05).

Results: The entry, apex, and angular deviations were 0.65 ± 0.32 mm, 0.66 ± 0.34 mm, and 1.52 ± 1.01°, respectively, with no statistically significant difference between the flap and flapless approaches (P > .05). No adverse events were encountered in any of the participants.

Conclusions: DIR accuracy in this clinical series was comparable to that reported for static and dynamic computer-assisted implant surgery. Robotic computer-assisted implant surgery may be useful for dental implant placement, potentially improving the quality and safety of the procedure.

Clinical relevance: The findings of this study showed that the ADIR system could be useful for dental implant surgery.

Keywords: Accuracy; Autonomous dental implant robotic; Deviation; Implant.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Katsoulis J, Pazera P, Mericske-Stern R (2009) Prosthetically driven, computer-guided implant planning for the edentulous maxilla: a model study. Clin Implant Dent Relat Res 11:238–425 - DOI - PubMed
    1. Buser D, Wittneben J, Bornstein MM, Grütter L, Chappuis V, Belser UC (2011) Stability of contour augmentation and esthetic outcomes of implant-supported single crowns in the esthetic zone: 3-year results of a prospective study with early implant placement postextraction. J Periodontol 82:342–349 - DOI - PubMed
    1. Buser D, Bornstein MM, Weber HP, Grütter L, Schmid B, Belser UC (2008) Early implant placement with simultaneous guided bone regeneration following single-tooth extraction in the esthetic zone: a cross-sectional, retrospective study in 45 subjects with a 2- to 4-year follow-up. J Periodontol 79:1773–1781 - DOI - PubMed
    1. D’Haese J, Ackhurst J, Wismeijer D, De Bruyn H (2000) Tahmaseb A (2017) Current state of the art of computer-guided implant surgery. Periodontol 73:121–133 - DOI
    1. Wu Y, Wang F, Fan S, Chow JK (2019) Robotics in dental implantology. Oral Maxillofac Surg Clin North Am 31:513–518 - DOI - PubMed

Substances

LinkOut - more resources