Active Hydrogen Free, Z-Isomer Selective Isatin Derived "Turn on" Fluorescent Dual Anions Sensor
- PMID: 38896304
- DOI: 10.1007/s10895-024-03762-1
Active Hydrogen Free, Z-Isomer Selective Isatin Derived "Turn on" Fluorescent Dual Anions Sensor
Abstract
An efficient and anions fluorescence "on-off" sensor of 1-(prop-2-yn-1-yl)-3-(quinolin-3-ylimino)indolin-2-one (PQI) has been developed for the selective sensing of dual anions of F- and NO3- ions in aqueous medium. Active hydrogen and Lewis acidic binding sites free, Z- isomer of isatin based π-conjugated quinoline exhibited excellent sensing activity against F- and NO3- ions in UV light. The fluorescence turns on the process accomplished via the PET "on-off" mechanism. The interaction between probe molecule and anions is thought to be a non-covalent interaction of the low electron density covalently bonded N-methylene moiety of propargyl isatin (-N-CH2-) of probe molecule with F- ion and the terminal acidic proton of propargyl group of isatin (-C≡C-H) with NO3- ions. The modes of anions binding with PQI and plausible mechanisms are proposed by 1H and 13C NMR titrations. The selectivity of anions sensing may be offered by the bucked structure of the Z-isomer. The calculated association constant values for PQI and F- and NO3- are ions 2.5 × 104 M-1 and 2.2 × 103 M-1, respectively, indicating strong binding interaction between the PQI and anions. The association nature of anions and probes was analyzed by a Jobs plot and the finding indicates both F- and NO3- ions are in 1:1 complexation with PQI. The limit of detection (LOD) of the probe with F- and NO3- ions is calculated and is to be 6.91 × 10-7 M and 9.93 × 10-7 M, respectively. The proposed PQI fluorophore possesses a low limit of detection (LOD) for both F- and NO3- ions which is within the WHO prescribed detection limit.
Keywords: Dual Anion sensor; Fluorophore; Isatin; Quinoline; Sigma-hole interaction.
© 2024. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.
Conflict of interest statement
Declarations. Ethics Approval: This is an observational study. The Indian Research Ethics Committee has confirmed that no ethical approval is required. Competing Interests: The authors declare no competing interests.
Similar articles
-
Dual-emissive ratiometric "turn-on" probe for real-time sensing of HSO4- in environmental samples and live cells.Spectrochim Acta A Mol Biomol Spectrosc. 2026 Jan 5;344(Pt 1):126629. doi: 10.1016/j.saa.2025.126629. Epub 2025 Jul 2. Spectrochim Acta A Mol Biomol Spectrosc. 2026. PMID: 40633326
-
Two-year follow-up study (PRIMROSE 3) to assess bone mineral density in subjects with uterine fibroids completing the PRIMROSE 1 and PRIMROSE 2 linzagolix trials.Hum Reprod Open. 2025 May 13;2025(3):hoaf025. doi: 10.1093/hropen/hoaf025. eCollection 2025. Hum Reprod Open. 2025. PMID: 40575397 Free PMC article.
-
Salicylidene-based dual-responsive 'turn on' fluorometric chemosensors for the selective detection of Zn2+, Al3+ and F- ions: theoretical investigation and applications in the live cell imaging of zebrafish larvae and molecular logic gate operation.J Mater Chem B. 2025 Jan 2;13(2):622-641. doi: 10.1039/d4tb01356e. J Mater Chem B. 2025. PMID: 39601190
-
A rapid and systematic review of the clinical effectiveness and cost-effectiveness of topotecan for ovarian cancer.Health Technol Assess. 2001;5(28):1-110. doi: 10.3310/hta5280. Health Technol Assess. 2001. PMID: 11701100
-
A rapid and systematic review of the clinical effectiveness and cost-effectiveness of paclitaxel, docetaxel, gemcitabine and vinorelbine in non-small-cell lung cancer.Health Technol Assess. 2001;5(32):1-195. doi: 10.3310/hta5320. Health Technol Assess. 2001. PMID: 12065068
References
-
- Zheng X, Bai B, Li Z, Wei J, Wang H, Li M, Xin H (2020) A fluorescent sensor for detection of grinding force and fluoride ion based on acylhydrazone derivative. Dye Pigment 175:108153
-
- Vinod V, Ramadevi D, Anakthi MV, Parathan TK, Basavaiah K (2020) Development of porphyrin-based chemosensor for highly selective sensing of fluoride ion in aqueous media. Microchem J 157:105028
-
- Zhou Y, Zhang JF, Yoon J (2014) Fluorescence and colorimetric chemosensors for fluoride-ion detection. Chem Rev 114:5511–5571 - PubMed
-
- Gauthama BU, Narayana B, Sarojini BK, Manjunatha JG, Suresh NK (2020) Colorimetric ‘naked eye’ sensor for fluoride ion based on isatin hydrazones via hydrogen bond formation: design, synthesis and characterization ascertained by Nuclear Magnetic Resonance, Ultraviolet-Visible, Computational and Electrochemical studies. Inorg Chem Commun 121:108216
Grants and funding
LinkOut - more resources
Full Text Sources
Research Materials
Miscellaneous