Repair of calcified bicuspid aortic valves using living autologous aortic wall leaflets

Affiliations
Case Reports

Repair of calcified bicuspid aortic valves using living autologous aortic wall leaflets

Timothy W James et al. JTCVS Tech. .
No abstract available

PubMed Disclaimer

Conflict of interest statement

Dr Rankin has been a consultant for BioStable Science and Engineering. All other authors reported no conflicts of interest. The Journal policy requires editors and reviewers to disclose conflicts of interest and to decline handling manuscripts for which they may have a conflict of interest. The editors and reviewers of this article have no conflicts of interest.

Figures

None
Autologous tissue valve for bicuspid valve repair created from aortic wall leaflets.
Figure 1
Figure 1
Steps in creating an autologous tissue valve. A, Calcified unicuspid valve is evident. B, Leaflet from ascending aortic tissue is being passed onto annular sutures. C, Autologous tissue valve is completed. D, Leaflets open well at the conclusion.
Figure 2
Figure 2
Echocardiography of autologous tissue valve. A, Calcified leaflets are moderately severely insufficient preoperatively. B, After repair, the autologous valve is fully competent. C, Repaired valve opens well during systole. D, Repaired aortic wall leaflets are tall and parallel during ejection.
None

References

    1. Miyahara S., Schneider U., Marganthaler L., Schaefers H.-J. (Almost) all nonstenotic bicuspid aortic valves should be preserved or repaired. Sem Thoracic Surg. 2019;31:656–660. - PubMed
    1. Gerdisch M.W., Reece B.T., Emerson D., et al. Early results of geometric ring annuloplasty for bicuspid aortic valve repair during aortic aneurysm surgery. J Thorac Cardiovasc Surg Tech. 2022;14:55–65. - PMC - PubMed
    1. de Meester C., Pasquet A., Gerber B.L., et al. Valve repair improves the outcome of surgery for chronic severe aortic regurgitation: a propensity score analysis. J Thorac Cardiovasc Surg. 2014;148:1913–1920. - PubMed
    1. Myers J.L., Clark J.B., James T.W., et al. Use of aortic wall patches as leaflet replacement material during aortic valve repair. J Thorac Cardiovasc Surg Tech. 2023;19:30–37. - PMC - PubMed
    1. Rankin J.S., Bone M.C., Fries P.M., Aicher D., Schaefers H.J., Crooke P.S. A refined hemispheric model of normal human aortic valve and root geometry. J Thorac Cardiovasc Surg. 2013;146:103–109. - PubMed

Publication types

LinkOut - more resources