Functionless retained pacing leads in the cardiovascular system. A complication of pacemaker treatment
- PMID: 3893487
- PMCID: PMC481852
- DOI: 10.1136/hrt.54.1.76
Functionless retained pacing leads in the cardiovascular system. A complication of pacemaker treatment
Abstract
Twenty one patients with retained endocardial pacemaker leads were followed during a total observation period of 1097 months to assess the incidence of complications. Two patients developed thrombosis and occlusion of the superior vena cava, which was relieved by the development of a collateral venous circulation. In one patient the broken tip of the lead migrated to a pulmonary artery but did not cause overt complications. The remaining patients were free of symptoms. One patient died for reasons unconnected with pacemaker treatment. The good toleration of retained pacemaker leads by most patients indicates that major surgical procedures to remove the lead should be reserved for patients with life threatening complications, such as persistent infection or dangerous migration of the lead or both.
Similar articles
-
Inferior vena cava thrombosis due to migration of retained functionless pacemaker electrode.Chest. 1982 Dec;82(6):785-6. doi: 10.1378/chest.82.6.785. Chest. 1982. PMID: 6754276
-
Unusual complications of endocardial pacing.J Thorac Cardiovasc Surg. 1980 Dec;80(6):934-40. J Thorac Cardiovasc Surg. 1980. PMID: 7431991
-
Major venous thrombosis: a complication of transvenous pacemaker electrodes.Br Heart J. 1980 Aug;44(2):158-61. doi: 10.1136/hrt.44.2.158. Br Heart J. 1980. PMID: 7426168 Free PMC article.
-
Venous complications after insertion of a transvenous pacemaker.Mayo Clin Proc. 1992 Mar;67(3):258-65. doi: 10.1016/s0025-6196(12)60103-7. Mayo Clin Proc. 1992. PMID: 1545594 Review.
-
Extraction of implanted transvenous pacing leads: a review of a persistent clinical problem.Am Heart J. 1991 Mar;121(3 Pt 1):881-8. doi: 10.1016/0002-8703(91)90203-t. Am Heart J. 1991. PMID: 2000756 Review.
Cited by
-
Frequency and clinical impact of retained implantable cardioverter defibrillator lead materials in heart transplant recipients.PLoS One. 2017 May 2;12(5):e0176925. doi: 10.1371/journal.pone.0176925. eCollection 2017. PLoS One. 2017. PMID: 28464008 Free PMC article.
-
Is there an adverse outcome from abandoned pacing leads?J Interv Card Electrophysiol. 2000 Oct;4(3):493-9. doi: 10.1023/a:1009860514724. J Interv Card Electrophysiol. 2000. PMID: 11046188
-
Pacemaker lead complications: when is extraction appropriate and what can we learn from published data?Heart. 2001 Mar;85(3):254-9. doi: 10.1136/heart.85.3.254. Heart. 2001. PMID: 11179258 Free PMC article. Review. No abstract available.
-
Upper Extremity Deep Vein Thrombosis and Asymptomatic Vein Occlusion in Patients With Transvenous Leads: A Systematic Review and Meta-Analysis.Front Cardiovasc Med. 2021 Aug 18;8:698336. doi: 10.3389/fcvm.2021.698336. eCollection 2021. Front Cardiovasc Med. 2021. PMID: 34490367 Free PMC article.
-
Extraction and replacement of permanent pacemaker leads through occluded vessels: use of extraction sheaths as conduits--balloon venoplasty as an adjunct.J Interv Card Electrophysiol. 1997 Dec;1(4):271-9. doi: 10.1023/a:1009724908464. J Interv Card Electrophysiol. 1997. PMID: 9869980
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical