Bridging the Gap Between Detection, Understanding, and Future Innovation in Patient-Ventilator Asynchronies
- PMID: 38942595
- PMCID: PMC11285488
- DOI: 10.4187/respcare.12153
Bridging the Gap Between Detection, Understanding, and Future Innovation in Patient-Ventilator Asynchronies
Conflict of interest statement
Dr Blanch is inventor of a US patent owned by Consorci Corporació Sanitària Parc Taulí: “Method and system for managed related patient parameters provided by a monitoring device”, US Patent No. 12/538,940. Dr Blanch owns stock options of BetterCare, a research and development spinoff of Consorci Corporació Sanitària Parc Taulí.
Figures

Similar articles
-
Emergency and critical care medicine residents' competency to identify patient ventilator asynchrony using a mechanical ventilator waveform analysis in Addis Ababa, Ethiopia: a multicenter cross-sectional study.BMC Med Educ. 2025 Feb 4;25(1):180. doi: 10.1186/s12909-025-06748-0. BMC Med Educ. 2025. PMID: 39905426 Free PMC article.
-
Evaluation of health care providers' ability to identify patient-ventilator triggering asynchrony in intensive care unit: a translational observational study in China.BMC Med Educ. 2025 Feb 4;25(1):182. doi: 10.1186/s12909-025-06638-5. BMC Med Educ. 2025. PMID: 39905371 Free PMC article.
-
Monitoring patient-ventilator asynchrony.Curr Opin Crit Care. 2016 Jun;22(3):246-53. doi: 10.1097/MCC.0000000000000307. Curr Opin Crit Care. 2016. PMID: 27070802 Review.
-
Asynchrony and dyspnea.Respir Care. 2013 Jun;58(6):973-89. doi: 10.4187/respcare.02507. Respir Care. 2013. PMID: 23709195 Review.
-
Patient-ventilator asynchrony.Curr Opin Crit Care. 2016 Feb;22(1):53-9. doi: 10.1097/MCC.0000000000000270. Curr Opin Crit Care. 2016. PMID: 26627539 Review.
Cited by
-
Optimizing Mechanical Ventilation: A Clinical and Practical Bedside Method for the Identification and Management of Patient-Ventilator Asynchronies in Critical Care.J Clin Med. 2025 Jan 2;14(1):214. doi: 10.3390/jcm14010214. J Clin Med. 2025. PMID: 39797296 Free PMC article. Review.
References
-
- Tobin MJ, Jubran A, Laghi F. Patient-ventilator interaction. Am J Respir Crit Care Med 2001;163(5):1059-1063. - PubMed
-
- Correger E, Murias G, Chacon E, Estruga A, Sales B, Lopez-Aguilar J, et al. Interpretación de las curvas del respirador en pacientes con insuficiencia respiratoria aguda. Med Intensiva 2012;36(4):294-306. - PubMed
-
- Chacón E, Estruga A, Murias G, Sales B, Montanya J, Lucangelo U, et al. Nurses’ detection of ineffective inspiratory efforts during mechanical ventilation. Am J Crit Care 2012;21(4):e89-93. - PubMed
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous