. 2024 Jun 7:27:101433.
doi: 10.1016/j.artd.2024.101433. eCollection 2024 Jun.

Stem Alignment With the Tapered Wedge Cementless Stem "Accolade II" Does Not Affect Bone Mineral Density Over 5 Years After Total Hip Arthroplasty

Affiliations

Stem Alignment With the Tapered Wedge Cementless Stem "Accolade II" Does Not Affect Bone Mineral Density Over 5 Years After Total Hip Arthroplasty

Masashi Tsujino et al. Arthroplast Today. .

Abstract

Background: This study aimed to investigate the relationship between 3-dimensional (3D) alignment and postoperative bone mineral density (BMD) changes with Accolade II tapered wedge stems, which have a different proximal shape from other tapered wedge stems, up to 5 years after primary total hip arthroplasty.

Methods: We retrospectively analyzed the hips of 89 patients who underwent total hip arthroplasty using the second-generation proximally coated cementless stem (Accolade II; Stryker Orthopedics, Mahwah, NJ) at our institution from 2014 to 2018 over a 5-year follow-up. We evaluated the relationship between stem alignment, measured using 3D-templating software, and BMD changes in the 7 Gruen zones and compared the data with those from a former study using other short taper-wedge stems.

Results: BMDs in zones 1 and 7 continued to decrease gradually every year after surgery, and BMD in zone 7 showed the largest decrease (21%) from baseline over 5 years. No correlation was found between stem alignment (varus/valgus, flexion/extension, and anteversion/retroversion) and changes in BMD in each zone over 5 years.

Conclusions: Our data showed no correlation between 3D stem alignment and changes in BMD in each Gruen zone over 5 years. This suggests that the Accolade II stem may fit better into any shape of the proximal medullary canal because of its unique characteristics.

Keywords: Bone mineral density; Stem alignment; Tapered wedge cementless stem; Total hip arthroplasty.

PubMed Disclaimer

Figures

Figure 1
Figure 1
Changes in BMD in each Gruen zone. Changes in BMD in zones 1 and 7 gradually decreased over time, and those in zone 3 were >100% at 5 years postoperatively. BMD, bone mineral density; Z, zone.
Figure 2
Figure 2
Difference of the proximal medial shape between Accolade II and a standard taper-wedge stem.

Similar articles

Cited by

References

    1. Wacha H., Domsel G., Herrmann E. Long-term follow-up of 1217 consecutive short-stem total hip arthroplasty (THA): a retrospective single center experience. Eur J Trauma Emerg Surg. 2018;44:457–469. - PubMed
    1. Ulivi M., Orlandini L.C., Meroni V., Lombardo M.D.M., Peretti G.M. Clinical performance, patient reported outcome, and radiological results of a short, tapered, porous, proximally coated cementless femoral stem results up to seven years of follow-up. J Arthroplasty. 2018;33:1133–1138. - PubMed
    1. Kaku N., Pramudita J.A., Yamamoto K., Tsumura H. Stress distributions of the short stem and the tapered wedge stem at different alignments: a finite element analysis study. J Orthop Surg Res. 2022;17:530. - PMC - PubMed
    1. Uçan V., Ezici V., Aliyev O., Uzer G., Tuncay İ., Yıldız F. Comparison of tapered-wedge short and standard-length femoral stems in single-stage bilateral direct anterior total hip arthroplasty. Int Orthop. 2021;45:3119–3127. - PubMed
    1. Kolisek F.R., Chughtai M., Mont M.A. Outcomes of second-generation tapered wedge femoral stem. Surg Technol Int. 2016;28:275–279. - PubMed

LinkOut - more resources