Creation and Validation of a Novel 3-Dimensional Pediatric Hip Ultrasound Model
- PMID: 38950383
- DOI: 10.1097/PEC.0000000000003155
Creation and Validation of a Novel 3-Dimensional Pediatric Hip Ultrasound Model
Abstract
Objectives: The aim of this study was to create and validate a 3-dimensional (3D) ultrasound model with normal and abnormal pediatric hip joint anatomy that is comparable to a pediatric hip joint in appearance and anatomy and replicates sonographic characteristics of a pediatric hip joint.
Methods: A 3D rendering of the bone and soft tissue was created from a computed tomography pelvic scan of a pediatric patient. This rendering was modified to include a unilateral joint effusion. The bone was 3D printed with a photopolymer plastic, whereas the soft tissue was cast with a silicone mixture in a 3D-printed mold. The effusion was simulated by injecting saline into the soft tissue cavity surrounding the bone. The ultrasound model was validated by pediatric point-of-care ultrasonographers at an international pediatric ultrasound conference.
Results: A pediatric hip ultrasound model was developed that simulates both normal and abnormal pediatric hip joint anatomy, each with an appropriately sized, measurable joint effusion. Validation by pediatric point-of-care ultrasonographers showed that the key aspects of a normal pediatric hip joint (femoral physis, sloped femoral neck, and adequate soft tissue) with an identifiable and measurable effusion were included in the ultrasound model.
Conclusions: In this study, we successfully created a cost-effective, reusable, and reproducible 3D pediatric hip ultrasound model. The majority of pediatric point-of-care ultrasonographers who evaluated the model agreed that this model is comparable to a pediatric patient for the purpose of teaching ultrasound skills and joint space measurement.
Copyright © 2024 Wolters Kluwer Health, Inc. All rights reserved.
References
-
- Mitchell C, Xiong PL, Cox BL, et al. Evaluating the effectiveness of a lower extremity venous phantom on developing ultrasound examination skills and confidence. Ultrasound . 2021;29:18–26.
-
- Fulton N, Buethe J, Gollamudi J, et al. Simulation-based training may improve resident skill in ultrasound-guided biopsy. AJR Am J Roentgenol . 2016;207:1329–1333.
-
- Kwon SY, Kim JW, Cho MJ, et al. The efficacy of cervical spine phantoms for improving resident proficiency in performing ultrasound-guided cervical medial branch block: a prospective, randomized, comparative study. Medicine (Baltimore) . 2018;97:e13765.
-
- GT Simulators by Global Technologies. Ultrasound and MRI Phantoms. Available at: https://www.gtsimulators.com/collections/ultrasound-and-mri-phantoms . Accessed April 26, 2022.
-
- Risler Z, Magee MA, Mazza JM, et al. A three-dimensional printed low-cost anterior shoulder dislocation model for ultrasound-guided injection training. Cureus . 2018;10:e3536.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous