. 2024 Jul:123:103907.
doi: 10.1016/j.jtherbio.2024.103907. Epub 2024 Jun 28.

Validity and reproducibility of the CALERA Research Sensor to estimate core temperature at different intensities of a cycling exercise in the heat

Affiliations

Validity and reproducibility of the CALERA Research Sensor to estimate core temperature at different intensities of a cycling exercise in the heat

William Martins Januário et al. J Therm Biol. 2024 Jul.

Abstract

Recent heatwaves have highlighted the importance of accurate and continuous core temperature (TCORE) monitoring in sports settings. For example, accentuated rises in TCORE caused by physical exercises under environmental heat stress increase the risk of heat illnesses. Thus, using valid and reproducible devices is essential to ensure safe sports practice. In this study, we assessed the validity and reproducibility of the Calera Research Sensor (CRS) in estimating the TCORE of male and female participants during cycling exercise in a hot environment. Seven male (age: 36.2 ± 10.1 years) and eight female cyclists (age: 30.1 ± 5.0 years) underwent two identical cycling trials in a dry-bulb temperature of 32 °C and relative humidity of 60%. The protocol consisted of an initial 10-min rest followed by a 60-min exercise comprising 10 min at 20%, 25 min at 55%, and 25 min at 75% of maximal aerobic power, and an additional 25 min of post-exercise recovery. TCORE was recorded simultaneously every minute using a gastrointestinal capsule (TGi) and the CRS (TSENSOR). Bland-Altman analysis was performed to calculate bias, upper (LCS) and lower (LCI) concordance limits, and the 95% confidence interval (95%CI). The maximum acceptable difference between the two devices was predetermined at ±0.4 °C. A mixed linear model was used to assess the paired differences between the two measurement systems, considering the participants, trials, and environmental conditions as random effects and the cycling stages as fixed effects. An intra-class correlation coefficient (ICC) of 0.98 was recorded when analyzing data from the entire experiment. A non-significant bias value of 0.01 °C, LCS of 0.38 °C, LCI of -0.35 °C, and CI95% of ±0.36 °C were found. When analyzing data according to the participants' sex, CRS reproducibility was high in both sexes: ICC values of 0.98 and 0.99 were reported for males and females, respectively. CI95% was 0.35 °C in experiments with males and 0.37 °C with females, thereby falling within the acceptable margin of difference. Therefore, CRS was considered valid (compared to TGi) and reproducible in estimating TCORE in both sexes at various intensities of cycling exercise in the heat.

Keywords: Core temperature; Heat illnesses; Heatwaves; Human health; Physical training.