Enhanced chlorine resistance of tap water-adapted Legionella pneumophila as compared with agar medium-passaged strains
- PMID: 3896142
- PMCID: PMC238566
- DOI: 10.1128/aem.50.1.21-26.1985
Enhanced chlorine resistance of tap water-adapted Legionella pneumophila as compared with agar medium-passaged strains
Abstract
Previous studies have shown that bacteria maintained in a low-nutrient "natural" environment such as swimming pool water are much more resistant to disinfection by various chemical agents than strains maintained on rich media. In the present study a comparison was made of the chlorine (Cl2) susceptibility of hot-water tank isolates of Legionella pneumophila maintained in tap water and strains passaged on either nonselective buffered charcoal-yeast extract or selective differential glycine-vancomycin-polymyxin agar medium. Our earlier work has shown that environmental and clinical isolates of L. pneumophila maintained on agar medium are much more resistant to Cl2 than coliforms are. Under the present experimental conditions (21 degrees C, pH 7.6 to 8.0, and 0.25 mg of free residual Cl2 per liter, we found the tap water-maintained L. pneumophila strains to be even more resistant than the agar-passaged isolates. Under these conditions, 99% kill of tap water-maintained strains of L. pneumophila was usually achieved within 60 to 90 min compared with 10 min for agar-passaged strains. Samples from plumbing fixtures in a hospital yielded legionellae which were "super"-chlorine resistant when assayed under natural conditions. After one agar passage their resistance dropped to levels of comparable strains which had not been previously exposed to additional chlorination. These studies more closely approximate natural conditions than our previous work and show that tap water-maintained L. pneumophila is even more resistant to Cl2 than its already resistant agar medium-passaged counterpart.
Similar articles
-
Susceptibility of Legionella pneumophila to chlorine in tap water.Appl Environ Microbiol. 1983 Nov;46(5):1134-9. doi: 10.1128/aem.46.5.1134-1139.1983. Appl Environ Microbiol. 1983. PMID: 6360045 Free PMC article.
-
Incubation of premise plumbing water samples on Buffered Charcoal Yeast Extract agar at elevated temperature and pH selects for Legionella pneumophila.Water Res. 2017 Oct 15;123:439-447. doi: 10.1016/j.watres.2017.06.077. Epub 2017 Jun 27. Water Res. 2017. PMID: 28689128
-
Glycine-containing selective medium for isolation of Legionellaceae from environmental specimens.Appl Environ Microbiol. 1981 Nov;42(5):768-72. doi: 10.1128/aem.42.5.768-772.1981. Appl Environ Microbiol. 1981. PMID: 7316506 Free PMC article.
-
Effects of metals on Legionella pneumophila growth in drinking water plumbing systems.Appl Environ Microbiol. 1985 Nov;50(5):1149-54. doi: 10.1128/aem.50.5.1149-1154.1985. Appl Environ Microbiol. 1985. PMID: 4091551 Free PMC article.
-
The Brief Case: A fatal case of Legionella pneumophila in an elderly patient.J Clin Microbiol. 2024 Nov 13;62(11):e0086324. doi: 10.1128/jcm.00863-24. Epub 2024 Nov 13. J Clin Microbiol. 2024. PMID: 39535209 Free PMC article. Review. No abstract available.
Cited by
-
Common features of opportunistic premise plumbing pathogens.Int J Environ Res Public Health. 2015 Apr 24;12(5):4533-45. doi: 10.3390/ijerph120504533. Int J Environ Res Public Health. 2015. PMID: 25918909 Free PMC article. Review.
-
Factors promoting survival of bacteria in chlorinated water supplies.Appl Environ Microbiol. 1988 Mar;54(3):649-54. doi: 10.1128/aem.54.3.649-654.1988. Appl Environ Microbiol. 1988. PMID: 3288119 Free PMC article.
-
Ammonia-oxidizing bacteria in a chloraminated distribution system: seasonal occurrence, distribution and disinfection resistance.Appl Environ Microbiol. 1990 Feb;56(2):451-62. doi: 10.1128/aem.56.2.451-462.1990. Appl Environ Microbiol. 1990. PMID: 2306090 Free PMC article.
-
Growth-supporting activity for Legionella pneumophila in tap water cultures and implication of hartmannellid amoebae as growth factors.Appl Environ Microbiol. 1988 Nov;54(11):2677-82. doi: 10.1128/aem.54.11.2677-2682.1988. Appl Environ Microbiol. 1988. PMID: 3214153 Free PMC article.
-
Detection of Legionella species in reclaimed water and air with the EnviroAmp Legionella PCR kit and direct fluorescent antibody staining.Appl Environ Microbiol. 1995 Feb;61(2):407-12. doi: 10.1128/aem.61.2.407-412.1995. Appl Environ Microbiol. 1995. PMID: 7574578 Free PMC article.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous